Gigabit PoE Switch Web User Manual PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES. IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATER PREVAILS.
Page 4
Gigabit PoE Switch Web User Manual Regulatory Information FCC Information Please take attention that changes or modification not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. FCC compliance: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
Page 5
Gigabit PoE Switch Web User Manual Industry Canada ICES-003 Compliance This device meets the CAN ICES-3 (A)/NMB-3(A) standards requirements.
Page 6
Gigabit PoE Switch Web User Manual Preface Applicable Models This manual is applicable to DS-3E15XXP series switch and guides you to complete the configuration and operation of the switch. About the Default • Default administrator account: admin. • Default IP address: 192.168.1.64. Symbol Conventions The symbols that may be found in this document are defined as follows.
Page 7
Gigabit PoE Switch Web User Manual • Keep body parts away from fan blades. Disconnect the power source during servicing. • Never place the device in an unstable location. The device may fall, causing serious personal injury or death. • This device is not suitable for use in locations where children are likely to be present. •...
Gigabit PoE Switch Web User Manual Chapter 1 Introduction DS-3E15XXP series switches are layer 2 PoE switches, providing advanced PoE power supply technology and gigabit networks design on the basis of high-performance access. The switches support Web management, and various layer 2 management protocols such as STP/RSTP, VLAN, link aggregation, SNMP, QoS to ensure stable data upload.
The computer and the switch are on the same network segment. Steps Note Take DS-3E1510P as an example. All figures in this manual are for illustration purpose only. 1. Enter the default IP 192.168.1.64 in the browser address bar. Figure 2-1 Activation...
Page 12
Gigabit PoE Switch Web User Manual 1) Go to System Management → Network Configuration . Figure 2-3 Network Configuration 2) Change the IP address, mask address, the gateway address, DNS and alternative DNS as needed. You can log in to the switch with the new IP address next time. Note You are recommended to change the network configuration to better manage the switch.
Gigabit PoE Switch Web User Manual Chapter 3 Device Management After logging in to the Web, you can go to Device Status to view the device status, including the device information, working status, port status, port statistics, and PoE status. Device Information Figure 3-1 Device Information •...
Page 14
Gigabit PoE Switch Web User Manual Working Status Figure 3-2 Working Status View the device running time, memory usage, and CPU usage. Port Status Figure 3-3 Port Status View the connection status, rate, duplex, and flow control of all ports. Port Statistics Figure 3-4 Port Statistics...
Page 15
Gigabit PoE Switch Web User Manual • Refreshing Rate: 10 sec, 30 sec, 60 sec, and Manually Refresh is available. • Refresh: When you choose Manually Refresh, you can click Refresh to refresh the statistics. • Reset: You can click Reset to clear all the statistics. PoE Status Figure 3-5 PoE Status View the complete appliance PoE status and the output power of each PoE port.
Gigabit PoE Switch Web User Manual Chapter 4 Switch Configuration 4.1 Port Configuration 4.1.1 Attribute Configuration The basic parameters can influence the working status of ports. Configure the parameters according to the actual situation. Steps 1. Go to Switch Configuration → Basic Configuration → Port Configuration → Attribute Configuration .
Gigabit PoE Switch Web User Manual Enable Enable or disable the port link. 3. Click Save to complete the configuration. 4.1.2 Port Mirroring Port mirroring monitors network traffic by sending copies of all incoming and outgoing packets from one port to a mirroring port. Steps 1.
Gigabit PoE Switch Web User Manual Parameter Description You can only set one port as the mirror port. Mirror Source The port that is under surveillance. You can set one or more ports as the mirror source. Mirror Direction Surveillance direction. •...
Gigabit PoE Switch Web User Manual Table 4-2 Parameters of Port Rate-Limiting Parameter Description Sending Rate- L imiting • Rate-Limiting: The data sending rate of the port is limited. • No Rate-Limiting: The data sending rate of the port is not limited. Sending Rate-...
Gigabit PoE Switch Web User Manual Figure 4-4 Storm Control 2. Select the port on which you want to enable storm control. Configure Storm Control as on. 3. Configure Storm Control Mode as Broadcast, Multicast, or Unknown Unicast. The threshold applies to the chosen mode.
Gigabit PoE Switch Web User Manual Figure 4-5 Long-Range Mode Configuration 2. Check Enable of the port. 3. Click Save to complete the configuration. 4.2 Link Aggregation Configuration Link aggregation is used to aggregate physical ports to create a logical channel. The advantages of link aggregation are higher transmission speed with wider bandwidth.
Page 22
Gigabit PoE Switch Web User Manual Figure 4-6 Load Balancing Source and Destination MAC Load balancing is performed based on source and destination MAC addresses on all the packets. 2. Add a link aggregation group in Aggregation Group Configuration. Figure 4-7 Link Aggregation Group 1) Click Add.
Gigabit PoE Switch Web User Manual Note • You can delete the ports from the Group Members by clicking Delete. • The rate, duplex, flow control, VLAN, and long-range configuration of all ports in one aggregation group must be the same. 4) Click OK to add a link aggregation group.
Gigabit PoE Switch Web User Manual 4.3.2 Configure a Port Steps 1. Select a port to configure on the Port Configuration page. Figure 4-10 VLAN Port Configuration 2. Click Edit. 3. Configure the port VLAN. - Access Port • An access port transports traffic to and from only the specified VLAN, usually the default VLAN, VLAN 1.
Gigabit PoE Switch Web User Manual Note All ports in the same aggregation group will be edited automatically at the same time. - Trunk Port • A trunk port is a port that is assigned to carry traffic for all the VLANs. •...
Page 26
Gigabit PoE Switch Web User Manual Figure 4-13 Scheduling Mode NORMAL First In First Out (FIFO) mode. Transmit the message coming in first. QoS is not enabled. Strict Priority mode. Transmit the message according to the actual priority configuration. Weighted Round Robin mode. Transmit the message according to the respective weight for low priority and high priority.
Gigabit PoE Switch Web User Manual Figure 4-14 Port Priority 3. Click Save to complete the configuration. 4.5 SNMP Configuration Simple Network Management Protocol (SNMP) is a widely used application-layer communication protocol for monitoring network performance. SNMP network is composed of the Network Management System (NMS) and the Agent.
Gigabit PoE Switch Web User Manual 4.5.1 SNMP Proxy Settings Steps 1. Go to Switch Configuration → L2 Configuration → SNMP Configuration → SNMP Proxy Settings to configure SNMP proxy. Figure 4-15 Proxy Settings 1) Enable SNMP. 2) Define the Community Name. Community Name The community name is an authentication mechanism, similar to a password, which is used to limit the data transmission between NMS and Agent.
Gigabit PoE Switch Web User Manual Figure 4-17 Add a Trap Table 4-3 Parameters of a Trap Parameter Description Target Host IP The IP address of NMS. It cannot be the broadcast or multicast address. Community Name The password used for authentication. Up to 32 bytes can be set.
Page 30
Gigabit PoE Switch Web User Manual Figure 4-18 Global Configuration 3. Configure the parameters. Table 4-4 Parameters of STP Parameter Description STP Mode • STP: Spanning-tree protocol. • RSTP: Rapid spanning-tree protocol. RSTP provides faster spanning tree convergence after a topology change.
Gigabit PoE Switch Web User Manual Parameter Description The range is from 6 to 40 seconds. The default is 20 seconds. Note The maximum aging time must meet the following conditions: • Maximum Aging Time ≥ (Hello Time + 1) •...
Page 32
Gigabit PoE Switch Web User Manual Figure 4-19 Port Priority 2. Configure the Port Priority. Port Priority • The lower the number is, the higher the priority is, the more probably the port becomes the root port. • The range is from 0 to 240, in increments of 16; the default is 128. Valid values are 0, 16, 32, 48, 64, 80, 96, 112, 128, 144, 160, 176, 192, 208, 224, and 240.
Gigabit PoE Switch Web User Manual 4.6.3 STP Status View You can check the global status of STP settings and the status of each port. Go to Switch Configuration → L2 Configuration → STP Configuration → STP Status . Figure 4-20 STP Status 4.7 PoE Management PoE Settings Figure 4-21 PoE Settings...
Page 34
Gigabit PoE Switch Web User Manual Note Enabling or disabling PoE has no influences on data transmission of the port. PoE Watchdog Figure 4-22 PoE Watchdog You can enable PoE watchdog to auto-detect and restart cameras that do not respond.
Gigabit PoE Switch Web User Manual Chapter 5 System Management 5.1 Time Sync Steps 1. Go to System Settings → Time Settings . You can view the Device Time. Figure 5-1 Time Settings 2. Select Time Zone. 3. Select Time Sync. Method 4.
Gigabit PoE Switch Web User Manual Figure 5-4 Device Operation Note Enter the login page automatically after you restart or restore the switch. Restart Click Restart to remotely restart the switch. Restore • Simply Restore: Except network configuration and user parameters, all of the other parameters are restored to the default settings.
Gigabit PoE Switch Web User Manual 5.4 Configuration File Import You can import the configuration file to configure the system easily. Steps 1. Go to System Management → System Maintenance → Export & Import . Figure 5-6 Export Configuration file 2.
Gigabit PoE Switch Web User Manual Steps 1. Go to System Management → Log Management . Figure 5-8 Log Management 2. Set search conditions, including Major Type, Minor Type, Start Time and End Time. 3. Click Search. Note A maximum of 2000 search results can display. Please narrow down the search scope if there are too many search results.
Gigabit PoE Switch Web User Manual Figure 5-9 Network Diagnostics 2. Enter the IP address of the server, and click PING. 5.8 User Management Regularly change the password can guarantee the security of the device. Steps 1. Go to System Management → User Management . 2.
Gigabit PoE Switch Web User Manual 5.9 Security Management Figure 5-11 Security Management The device supports SSH security service. SSH can prevent the information leakage in the remote management of the device. SSH is disabled by default. Note The user name of SSH is root, and the password is the device login password. SADP After enabling SADP, you can activate the device, change the password and the network information, and etc.