Fault Code Register
Extra Supply Fls
Auxiliary supply
Overcurrent protection for the auxiliary supply has tripped.
•
Check the auxiliary stop connections for short circuits.
Reset the system by switching the main switch off and on.
Contact a Volvo Penta workshop if the fault remains.
ExtSTOP Active Fls
Emergency Stop Switch
•
Check emergency stop button if any. Reset if necessary.
Fls
Miscellaneous system faults
Engine performance can be affected.Several possible causes of engine problems are described below.
•
Battery voltage incorrect
Check belt tension. Refer to Drive belt, check and change, page 56.
Check battery fluid level. Refer to Battery, page 74.
•
Fuel pressure incorrect.
Engine performance can be affected.
•
Communication failure
Gear automatically set to neutral. Engine performance can be affected.
•
Oil pressure too low.
Engine power is reduced.
Check the oil level in the engine. Refer to Oil level, checking and topping up, page 57.
Check that no leakage occurs.
•
Sensor failure
Contact a Volvo Penta workshop if the fault remains.
Fls Throttle In
Engine speed demand to system lacking
•
Check Control Lever
FuelDelPress Wrn
Fuel pressure too low.
•
Check fuel level.
•
Check that the fuel filters are not blocked. Replace filters if necessary. Refer to Engine Fuel Filter
Replacement, page 62
•
Check for fuel leakage.
42