Page 1
Installation and operating instructions ELECTRIC FRYERS FOR PROFESSIONAL USE FEM-6 FEM-2/6 FE-8 FE-2/8 FE-10 FE-2/10 FME-10 FME-2/10 FME-15 FME-2/15 FPE-20 FPE-25 FMPE-20 FMPE-25 FMPE-30 Model LIBR.ISTR.FE FME FPE Code 563009301 Review 1 Edition date 28/01/2020 Language English LOTUS S.p.A. Via Calmaor, 46...
INTRODUCTION 1 INTRODUCTION Installation drawing FIG. 1 FE-10 FE-2/10 A Data Plate B Electrical connection Instructions in original language...
Page 4
INTRODUCTION FIG. 2 FEM-6 FE-8 FEM-2/6 FE-2/8 A Data Plate B Electrical connection Instructions in original language...
Page 5
INTRODUCTION FIG. 3 FME-10 FME-15 A Data Plate B Electrical connection Instructions in original language...
Page 6
INTRODUCTION FIG. 4 FMPE-20 FMPE-25 FMPE-30 A Data Plate B Electrical connection FIG. 5 FPE-20 FPE-25 A Data Plate B Electrical connection Instructions in original language...
Page 7
INTRODUCTION WIRING DIAGRAM FEM-6 FEM-2/6 1 Switch 2 Microswitch 3 Power supply terminal board 4 Heating element 5 White indicator light 6 Green indicator light 7 Contactor 8 Safety thermostat 9 Thermostat Instructions in original language...
Page 8
INTRODUCTION WIRING DIAGRAM FE-8, FE-2/8, FE-10, FE-2/10, FME-10, FME-2/10, FME-15, FME-2/15, FPE-20, FPE-25, FMPE-20, FMPE-25 1 Switch 2 Microswitch 3 Power supply terminal board 4 Switching terminal board 5 Heating element 6 White indicator light 7 Green indicator light 8 Contactor 9 Thermostat 10 Safety thermostat Instructions in original language...
Page 9
INTRODUCTION WIRING DIAGRAM FMPE-30 1 Switch 2 Microswitch 3 Power supply terminal board 4 Switching terminal board 5 Heating element 6 White indicator light 7 Green indicator light 8 Contactor 9 Thermostat 10 Safety thermostat Instructions in original language...
GENERAL INFORMATION 2 GENERAL INFORMATION Declaration of compliance The manufacturer declares that the appliances comply with the requirements of the regulation GAR 2016/426 for the gas part and directive 2014/30/EU,2014/35/EU for the electrical part. Installation must be performed in compliance with current regulations, especially with regard to ventilation of the premises and the exhaust gas evacuation system.
GENERAL INFORMATION User information, RAEE Directive on waste electrical and electronic equipment With regard to the regulatory framework of reference of the European Community, we remind the user of the following: · Used AAE (Electrical and Electronic Equipment) products must be collected separately ·...
Electrical technical data table FE FMPE MAXIMUM MAXIMUM Silicon POWER MODEL DIMENSIONS POWER SUPPLY INPUT (A) POWER (kW) SUPPLY CABLE FEM-6 30x51x25h 230V~ 50/60Hz 3 x 2,5 mm² FEM-2/6 60x51x25h 230V~ 50/60Hz 3 x 2,5 mm² FE-8 30x51x25h 400V~3N 50/60Hz 5 x 1,5 mm²...
INSTALLATION 3 INSTALLATION Delivery checks On delivery, it is important to check the following: · External conditions of the packaging · The general status of the equipment · The conformity of the model with the information in the technical data plate and the instruction manual ·...
Page 14
INSTALLATION Warning Installation operations, any conversion to other types of gas and start-up must only be performed by qualified personnel, in accordance with current regulations. Gas systems, electrical connections and premises where the appliances are installed must comply with current regulations in the country of installation;...
INSTRUCTIONS FOR USE 4 INSTRUCTIONS FOR USE General information This appliance must only be used for its expressly intended purpose for cooking or heating food. Any other use is considered improper. The appliance is also intended for industrial use and must only be used by personnel trained for use and aware of the risks that the hot element entails.
INSTRUCTIONS FOR USE If using the fryer with products other than oil (lard, for example) that have considerable thermal inertia, it is necessary to set the thermostat to a low value (e.g. 110°C) during the first cycle (not starting cold). The thermostat can be set to the maximum only after the entire mass has melted ...
MAINTENANCE 5 MAINTENANCE Routine When using the appliance over time, it is essential to perform regular maintenance to ensure safe operation. We therefore recommend stipulating a service contract. Caution Maintenance must only be performed by specialist personnel in compliance with current ...
MAINTENANCE Spare parts It is possible to replace parts such as the valve, the piezoelectric or the ignition control unit (depending on the type of appliance) or the gas pipes easily and quickly. To replace such parts, proceed as follows: ...
CLEANING 6 CLEANING Routine cleaning Caution The use of flammable fluids to clean the appliance is forbidden To ensure hygiene and the durability of the appliance, perform external cleaning on a regular basis, taking care not to damage the cables and the electrical connections. Before starting cleaning, disconnect the appliance from the power supply.