*0517I360* Release 0517I360 Language Art-Net™ Designed by and Copyright Artistic Licence Holdings Ltd All other trademarks, both marked and not marked, are the property of their respective owners. Le informazioni contenute in questo documento sono state attentamente redatte e controllate. Tuttavia non è assunta alcuna responsabilità per eventuali inesattezze. Tutti i diritti sono riservati e questo documento non può...
INDEX: 1 - Symbols ............................4 2 - General Warning .........................5 3 - Important Safety Information ......................5 3.1 Fire prevention ..........................5 3.2 Prevention of electric shock ......................5 3.3 Safety ..............................6 3.4 Level of protection against the penetration of solid and liquid objects ........... 7 3.5 Waste Electrical and Electronic Equipment (WEEE) directive ............
1- Symbols Symbol used: Meaning: General risk. Electric shock risk. Hot surface. Suitable for indoor use only. Maximum operating ambient temperature. Minimum distance from illuminated objects. Do not stare at the operating light source. Photobiological safety risk group. Never expose the front lens to sunlight or any strong artificial light source from any angle to avoid damage of head internal parts.
• Class I appliance: connection must be made to a mains system fitted with an efficient earthing. • The level of technology inherent in the SYNERGY 7 PROFILE requires the assistance of specialised personnel for all servicing. Please refer to an authorised DTS service centre.
3- Important Safety Information 3.3 Safety: • Risk Group 2 product according to IEC 62471. Do not look directly into the light output and do not view the light beam with optical instruments or any device that may concentrate the beam. May be harmful to the eyes and skin.
3- Important Safety Information 3.4 Level of protection against the penetration of solid and liquid objects: • The projector is classified as an ordinary appliance and its protection level against the penetration of solid and liquid objects is IP20. • The projector contains electric and electronic components which should under no circumstances come into contact with oil, water or any other liquid.
Page 9
- 16 bit index for blade system rotation • Standard, Silent and Ultra-silent operation modes • Noise level at Ultra-silent mode: 36dBA @ 1 m (normal operation, full power) • Internal operating system updatable via DTS dongle firmware uploader Pan & Tilt • Pan: 540°...
/ horizontal. • Professional G-QUICK clamp - max load 100 Kg (code 0521A037) not indicated for horizontal load. • Safety cable 5 x 600 mm (Max load 60 Kg) (code 0521A038) • DTS Dongle firmware uploader (code 03.LA.206)
7 PROFILE is moving. Four 1/4 turn Fast Locks connections placed in the base of the unit allow to hang the SYNERGY 7 PROFILE by using two Omega brackets (provided in the box) in conjunction with Aliscaf clamp (available on demand).
9.1- Safety cable A safety cable must be securely fixed to the SYNERGY 7 PROFILE and to the suspension truss in order to avoid the fixture accidentally falling should the main fixing point fail. The safety cable used must be approved by a notified body according to IEC 60598-2-17 and must be capable of bearing at least 10 times the weight of the unit.
10- Mains Connection SYNERGY 7 PROFILE operates at 100-240Vac 50-60 Hz. Prior to connecting the unit to your mains supply, ensure that the model in your possession correctly matches the mains supply available. For connection purposes, ensure that your plug is capable of supporting 6,5 amps at 230Vac or 14 amps at 100Vac each unit connected.
11- DMX Signal Connection The unit operates using the digital DMX 512 signal. Connection between the mixer and the projector or between projectors must be carried out using a two pair screened ø 0.5 mm cable and a XLR 5 or 3 pins connector. Ensure that the conductors do not touch each other.
11.1-DMX Addresses SYNERGY 7 PROFILE can be controlled with 52 DMX channels (Default) or 61 DMX channels. In order to use the unit in 52 DMX channels mode (Default), set the following addresses on the mixer: Projector 1 A001 Projector 2 A053 If you want to select the next projector, just add “52”...
12- Art-Net / sACN Signal Connection 12.2-Ethernet to RDM/DMX operation For Ethernet to RDM/DMX operation connect the mixer Art-Net / sACN signal via Ethernet switch to the etherCON RJ45 input connector of the first unit only. In this configuration the first unit works as an Ethernet to DMX converter and sends RDM/DMX signal to its DMX output connector.
13- RDM Functions By using a RDM controller it is possible to read / set DMX address, DMX mode and other parameters. SYNERGY 7 PROFILE accepts the following RDM commands: RDM Device Model ID: 0x0019 RDM PID DESCRIPTION RDM PID VALUE Category –...
Please follow the procedure below to perform the update: 1. Connect the DTS Dongle Firmware Uploader to a spare USB port on the PC. 2. Connect the unit DMX input to the DTS Dongle Firmware Uploader DMX output with a standard DMX cable and turn ON the unit.
Using these options, it is possible to change the fixture’s setting. Changing the DTS settings can vary the functions of the unit so that it does not respond to the DMX 512 used to control it. Carefully follow the instructions below before carrying out any variations or selections.
Page 24
16- Display Functions MAIN MENU LEVEL 1 LEVEL 2 LEVEL 3 FUNCTION Allows to disable Ethernet NETWORK INPUT DISABLED operation (Default). Allows to select Art-Net as input ARTNET control signal protocol. Allows to select sACN as input SACN control signal protocol. Fixed IP address with IP ADDR MODE DEFAULT...
Page 25
16- Display Functions MAIN MENU LEVEL 1 LEVEL 2 LEVEL 3 FUNCTION Reverses display's reading DISPLAY FLIP AUTO depending on the mounting ON THE GROUND position. Automatic, on the ground SUSPENDED or suspended. Default = AUTO Display stand-by disabled (Default). STANDBY DISABLED Display goes OFF after 5 seconds.
Page 26
16- Display Functions MAIN MENU LEVEL 1 LEVEL 2 LEVEL 3 FUNCTION Default = 0 NO DMX SINGLE CUE BLADE SYS ROT 0 - 255 Default = 0 ACTION BLADE 1 INS 0 - 255 Default = 128 BLADE 1 ROT 0 - 255 Default = 0 BLADE 2 INS...
Page 27
(Hz) in order to reduce flickering in the process of camera recordings. Range = 610 Hz – 5 KHz Default = 1000 Hz SYNERGY 7 PROFILE Unit model, motors firmware SYSTEM INFO SOFTWARE 10 JUN 2020 release date, Motors and LED Driver MOTOR: V.10...
Page 28
16- Display Functions MAIN MENU LEVEL 1 LEVEL 2 LEVEL 3 FUNCTION Lock the Pan to the desired value. RESERVED ENTER CODE PAN LOCK NO = Default. 0 – 255 (code 100) Lock the Tilt to the desired value. TILT LOCK NO = Default.
Page 29
16- Display Functions MAIN MENU LEVEL 1 LEVEL 2 LEVEL 3 FUNCTION Manual mode with functions value MANUAL PAN MSB 0 - 255 selectable by user. CONTR. 52 CH DMX PERSONALITY Default = 128 Default = 128 PAN LSB 0 - 255 Default = 128 TILT MSB 0 - 255...
17- Error Messages ERROR SHOWN ON DISPLAY APPEARS WHEN -Pan motor fault -Pan encoder fault -Pan motor driver on Pan&Tilt PCB fault -Wiring connection between Pan encoder and Pan&Tilt PCB fault -Pan locked PAN LOCKED -Pan motor fault -Pan encoder fault -Pan motor driver on Pan&Tilt PCB fault -Wiring connection between Pan encoder and Pan&Tilt PCB fault -Tilt motor fault...
Page 31
17- Error Messages ERROR SHOWN ON DISPLAY APPEARS WHEN -Pan&Tilt PCB driver fault BUS 5 MOTORS CARD 5 -5 Motors PCB (5)* driver fault -5 Motors PCB (5)* input voltage missing -Internal Bus wiring connection fault -Pan&Tilt PCB driver fault BUS LED DRIVER CARD 1 -LED Driver PCB 1 (MASTER)* driver fault -LED Driver PCB 1 (MASTER)* input voltage missing...
Page 32
17- Error Messages ERROR SHOWN ON DISPLAY APPEARS WHEN -Gobo 2 wheel/index motor fault GOBO 2 WHEEL / GOBO 2 INDEX -Gobo 2 wheel/index motor driver on 5 Motors PCB (5)* fault OR CARD 5 - RESET LINE 3 -Gobo 2 wheel/index magnet missing -Gobo 2 wheel/index hall sensor PCB fault -Profiler index motor fault PROFILER INDEX...
19- Opening The Projector Housing It is possible to inspect the inside of the projector by removing the cover as indicated below. WARNING! Disconnect mains before opening the projector housing. 1) Using a flat bladed screwdriver loose the 4 “¼ turn” screws which fix the head covers on both sides.
20- Rotating Gobo Dimensions Replacement / custom gobos should be made in dichroic glass. For gobos removing/replacing procedure please refer to an authorised DTS service centre. Gobo dimensions are as follows: ROTATING GOBO WHEEL 1: ø external (ED) = 34.9 mm + 0 / - 0,2 mm ø...
Periodically check the lubrification of all components, particularly the parts subject to high temperatures. If necessary, lubrificate with suitable lubrificant, available from your DTS distributor. Check the tension of the belts and adjust it if necessary. Electrical components Check all electrical components for efficient earthing and proper connection of all connectors, refastening if necessary.
23- DMX Protocol DMX Personality 1: 52 CHANNELS MODE (DEFAULT) PAN msb PAN lsb TILT msb TILT lsb SPEED MOVEMENT reserved DIMMER msb DIMMER lsb SHUTTER FILTERS WHEEL COLOUR WHEEL COLOUR WHEEL MODE CYAN MAGENTA YELLOW GEL FILTERS EMULATION / COLOUR EFFECTS GOBO 1 GOBO 1 ROTATION / INDEX msb GOBO 1 ROTATION / INDEX lsb...
Page 38
PAN msb PAN lsb TILT msb TILT lsb SPEED MOVEMENT DMX value Function 000-009 Fast movement 010-025 Standard movement 026-127 Vector mode from fast to slow 128-247 Variable time reaction to dmx signal (fast to slow) 248-250 Silent movement 251-255 Snap movement reserved DMX value...
Page 39
COLOUR WHEEL FULL COLOUR (if channel 12 “COLOUR MODE” = DMX range value 0-63) DMX value Function 000-009 Open 010-058 Colour 1 059-107 Colour 2 108-156 Colour 3 157-205 Colour 4 206-255 Colour 5 HALF COLOUR (if channel 12 “COLOUR MODE” = DMX range value 64-127) DMX value Function 000-009...
Page 40
YELLOW DMX value Function 000-255 Proportional colour DMX value Function 000-255 Proportional colour GEL FILTERS EMULATION DMX value Function 000-009 No function 010-020 19 FIRE 021-025 20 MEDIUM AMBER 026-030 25 SUNSET RED 031-035 68 SKY BLUE 036-040 101 YELLOW 041-045 104 DEEP AMBER 046-050...
Page 41
GOBO 1 ROTATION/INDEX msb GOBO 1 ROTATION/INDEX lsb DMX value Function MSB.LSB-MSB.LSB INT16-INT16 000.000-127.255 Proportional index 0°-360° 00000-32767 128.000-180.255 CCW gobo rotation (max to min) 32768-46335 181.000-202.255 Stop 46336-51967 203.000-255.255 CW gobo rotation (min to max) 51968-65535 GOBO 1 SHAKE DMX value Function 000-009...
Page 42
GOBO 2 ROTATION/INDEX msb GOBO 2 ROTATION/INDEX lsb DMX value Function MSB.LSB-MSB.LSB INT16-INT16 000.000-127.255 Proportional index 0°-360° 00000-32767 128.000-180.255 CCW gobo rotation (max to min) 32768-46335 181.000-202.255 Stop 46336-51967 203.000-255.255 CW gobo rotation (min to max) 51968-65535 GOBO 2 SHAKE DMX value Function 000-009...
Page 43
BLADES SYSTEM ROTATION DMX value Function 000-126 Position from -45° to 0° 127-128 0° position 129-255 Position from 0° to 45° BLADE 1 INSERTION DMX value Function 000-255 Open to fully inserted BLADE 1 ROTATION DMX value Function 000-127 Position from -30° to 0° 0°...
Page 44
BLADES EFFECTS DMX value Function DMX value Function 000-009 No function 110-111 Macro 51 010-011 Macro 1 112-113 Macro 52 012-013 Macro 2 114-115 Macro 53 014-015 Macro 3 116-117 Macro 54 016-017 Macro 4 118-119 Macro 55 018-019 Macro 5 120-121 Macro 56 020-021...
Page 48
PRISM MODE DMX value Function 000-009 No function 010-049 Prism 1 inserted after zoom lens 050-089 Prism 2 inserted after zoom lens 090-129 Prism 1+2 inserted after zoom lens 130-169 Prism 1 inserted between focus and zoom lenses 170-209 Prism 2 inserted between focus and zoom lenses 210-255 Prism 1+2 inserted...
Page 49
FOCUS msb FOCUS lsb DMX value Function 000-255 Linear focus ZOOM DMX value Function 000-255 Linear zoom FIXTURE CONTROL DMX value Function 000-009 0 - No effect 010-024 1 – SMOOTH DIMMING OFF 025-026 2 - SMOOTH DIMMING 1 027-028 3 - SMOOTH DIMMING 2 029-030 4 - SMOOTH DIMMING 3...
Page 50
FIXTURE CONTROL DMX value Function 135-136 41 - CMY / CTO SPEED 1 (Speed value must not be set while CMY filters are moving during programming) 137-138 42 - CMY / CTO SPEED 2 (Speed value must not be set while CMY filters are moving during programming) 139-140 43 - CMY / CTO SPEED 3...
Page 51
FREQUENCY FINE DMX value Function 000-009 No effect 010-255 Led frequency: 75% to 125% of base frequency RESET DMX value Function 000-009 No effect 010-075 PAN TILT reset 076-095 HEAD MOTORS reset 096-115 Gobo wheel reset 116-135 Colour wheel reset 136-155 CMY/CTO reset 156-175...
23- DMX Protocol DMX Personality 2: 61 CHANNELS MODE PAN msb PAN lsb TILT msb TILT lsb SPEED MOVEMENT reserved DIMMER msb DIMMER lsb SHUTTER FILTERS WHEEL COLOUR WHEEL COLOUR WHEEL MODE CYAN MAGENTA YELLOW GEL FILTERS EMULATION / COLOUR EFFECTS GOBO 1 GOBO 1 ROTATION / INDEX msb GOBO 1 ROTATION / INDEX lsb...
Page 53
PAN msb PAN lsb TILT msb TILT lsb SPEED MOVEMENT DMX value Function 000-009 Fast movement 010-025 Standard movement 026-127 Vector mode from fast to slow 128-247 Variable time reaction to dmx signal (fast to slow) 248-250 Silent movement 251-255 Snap movement reserved DMX value...
Page 54
COLOUR WHEEL FULL COLOUR (if channel 12 “COLOUR MODE” = DMX range value 0-63) DMX value Function 000-009 Open 010-058 Colour 1 059-107 Colour 2 108-156 Colour 3 157-205 Colour 4 206-255 Colour 5 HALF COLOUR (if channel 12 “COLOUR MODE” = DMX range value 64-127) DMX value Function 000-009...
Page 55
YELLOW DMX value Function 000-255 Proportional colour DMX value Function 000-255 Proportional colour GEL FILTERS EMULATION DMX value Function 000-009 No function 010-020 19 FIRE 021-025 20 MEDIUM AMBER 026-030 25 SUNSET RED 031-035 68 SKY BLUE 036-040 101 YELLOW 041-045 104 DEEP AMBER 046-050...
Page 56
GOBO 1 ROTATION/INDEX msb GOBO 1 ROTATION/INDEX lsb DMX value Function MSB.LSB-MSB.LSB INT16-INT16 000.000-127.255 Proportional index 0°-360° 00000-32767 128.000-180.255 CCW gobo rotation (max to min) 32768-46335 181.000-202.255 Stop 46336-51967 203.000-255.255 CW gobo rotation (min to max) 51968-65535 GOBO 1 SHAKE DMX value Function 000-009...
Page 57
GOBO 2 ROTATION/INDEX msb GOBO 2 ROTATION/INDEX lsb DMX value Function MSB.LSB-MSB.LSB INT16-INT16 000.000-127.255 Proportional index 0°-360° 00000-32767 128.000-180.255 CCW gobo rotation (max to min) 32768-46335 181.000-202.255 Stop 46336-51967 203.000-255.255 CW gobo rotation (min to max) 51968-65535 GOBO 2 SHAKE DMX value Function 000-009...
Page 58
BLADES SYSTEM ROTATION msb BLADES SYSTEM ROTATION lsb DMX value Function 000-126 Position from -45° to 0° 127-128 0° position 129-255 Position from 0° to 45° BLADE 1 INSERTION msb BLADE 1 INSERTION lsb DMX value Function 000-255 Open to fully inserted BLADE 1 ROTATION msb BLADE 1 ROTATION lsb DMX value...
Page 59
BLADE 4 ROTATION lsb DMX value Function 000-127 Position from -30° to 0° 0° position 129-255 Position from 0° to 30° BLADES EFFECTS DMX value Function DMX value Function 000-009 No function 110-111 Macro 51 010-011 Macro 1 112-113 Macro 52 012-013 Macro 2 114-115...
Page 63
PRISM MODE DMX value Function 000-009 No function 010-049 Prism 1 inserted after zoom lens 050-089 Prism 2 inserted after zoom lens 090-129 Prism 1+2 inserted after zoom lens 130-169 Prism 1 inserted between focus and zoom lenses 170-209 Prism 2 inserted between focus and zoom lenses 210-255 Prism 1+2 inserted...
Page 64
FOCUS msb FOCUS lsb DMX value Function 000-255 Linear focus ZOOM DMX value Function 000-255 Linear zoom FIXTURE CONTROL DMX value Function 000-009 0 - No effect 010-024 1 – SMOOTH DIMMING OFF 025-026 2 - SMOOTH DIMMING 1 027-028 3 - SMOOTH DIMMING 2 029-030 4 - SMOOTH DIMMING 3...
Page 65
FIXTURE CONTROL DMX value Function 135-136 41 - CMY / CTO SPEED 1 (Speed value must not be set while CMY filters are moving during programming) 137-138 42 - CMY / CTO SPEED 2 (Speed value must not be set while CMY filters are moving during programming) 139-140 43 - CMY / CTO SPEED 3...
Page 66
FREQUENCY FINE DMX value Function 000-009 No effect 010-255 Led frequency: 75% to 125% of base frequency RESET DMX value Function 000-009 No effect 010-075 PAN TILT reset 076-095 HEAD MOTORS reset 096-115 Gobo wheel reset 116-135 Colour wheel reset 136-155 CMY/CTO reset 156-175...
Need help?