therefore take your measurements in the same quiet conditions
and when you feel relaxed! Take at least two readings every time
(in the morning and in the evening) and average the measurements.
• It is quite normal for two measurements taken in quick succes-
sion to produce significantly different results.
• Deviations between measurements taken by your doctor or in
the pharmacy and those taken at home are quite normal, as
these situations are completely different.
• Several measurements provide much more reliable information
about your blood pressure than just one single measurement.
• Leave a small break of at least 15 seconds between two
measurements.
• If you suffer from an irregular heartbeat (arrhythmia, see
«Section 5.»), measurements taken with this device should be
evaluated with your doctor.
• The pulse display is not suitable for checking the
frequency of heart pacemakers!
• If you are pregnant, you should monitor your blood pressure
very closely as it can change drastically during this time!
This monitor is specially tested for use in pregnancy and
pre-eclampsia. When you detect unusual high readings in
pregnancy, you should measure again after 4 hours. If the
reading is still too high, consult your doctor or gynecologist.

How do I evaluate my blood pressure?

Table for classifying home blood pressure values in adults in
accordance with the international Guidelines (ESH, AHA, JSH).
Data in mmHg.
Range
Systolic Diastolic Recommendation
blood pressure too
 100
low
1. blood pressure
100 - 130 60 - 80
optimum
2. blood pressure
130 - 135 80 - 85
elevated
3. blood pressure too
135 - 160 85 - 100 Seek medical
high
4. blood pressure
160 
dangerously high
The higher value is the one that determines the evaluation.
Example: a blood pressure value of 140/80 mmHg or a value of
130/90 mmHg indicates «blood pressure too high».
BP A2 Easy
 60
Consult your
doctor
Self-check
Self-check
advice
100 
Urgently seek
medical advice!

3. Using the Device for the First Time

Inserting the batteries

After you have unpacked your device, first insert the batteries. The
battery compartment 5 is on the bottom of the device. Insert the
batteries (4 x 1.5 V, size AA), thereby observing the indicated polarity.

Selecting the correct cuff

Microlife offers different cuff sizes. Select the cuff size to match the
circumference of your upper arms (measured by close fitting in the
centre of the upper arm).
Cuff size
for circumference of upper arm
S
17 - 22 cm
M
22 - 32 cm
M - L
22 - 42 cm
L
32 - 42 cm
L - XL
32 - 52 cm
Optional preformed cuffs «Easy» are available for better
fitting and comfort.
Only use Microlife cuffs.
Contact your local Microlife Service if the enclosed cuff 6 does
not fit.
Connect the cuff to the device by inserting the cuff connector 7
into the cuff socket 3 as far as it will go.
4. Taking a Blood Pressure Measurement using this
Device
Checklist for taking a reliable measurement
1. Avoid activity, eating or smoking immediately before the
measurement.
2. Sit down for at least 5 minutes before the measurement and relax.
3. Always measure on the same arm (normally left). It is recom-
mended that doctors perform double arm measurements on a
patients first visit in order to determine which arm to measure in
the future. The arm with the higher blood pressure should be
measured.
4. Remove close-fitting garments from the upper arm. To avoid
constriction, shirt sleeves should not be rolled up - they do not
interfere with the cuff if they are laid flat.
5. Always ensure that the correct cuff size is used (marking on the
cuff).
• Fit the cuff closely, but not too tight.