Page 1
K18854, K18864, K18855, K18865 Low Temperature Torque Apparatus Operation and Instruction Manual REV B Koehler Instrument Company, Inc. 1595 Sycamore Avenue • Bohemia, New York 11716-1796 • USA Toll Free: 1-800-878-9070 (US only) • Tel: +1 631 589 3800 • Fax: +1 631 589 3815 http://www.koehlerinstrument.com •...
Page 2
Low Temperature Torque Apparatus Operation and Instruction Manual K18854,55,64,65-Manual...
Page 3
FTM 791-334 This unit is tested before it leaves the factory, to ensure total functionality and compliance to the above specifications and ASTM standards. Test and inspection records are on file for verification. Jesse Kelly Application Engineer Koehler Instrument Company K18854,55,64,65-Manual...
Page 4
Low Temperature Torque Apparatus Operation and Instruction Manual K18854,55,64,65-Manual...
Page 5
Low Temperature Torque Apparatus Operation and Instruction Manual K18854,55,64,65-Manual...
Page 6
Low Temperature Torque Apparatus Operation and Instruction Manual K18854,55,64,65-Manual...
Page 7
Responsibility for Registration and Annual Reporting: Koehler will not sell directly to end users in the EU and so has no responsibility to register within each EU state and to make annual reports. Koehler declares that this responsibility is born by the importer who is the first level of the distribution chain and is subject to producer responsibility.
Page 8
WEEE Marking Since Koehler products are subject to the WEEE Directive we must display the WEEE symbol shown above in accordance with European Standard EN 50419 on the equipment. It must be indelible, at least 5mm in height, and clearly legible.
Low Temperature Torque Apparatus Operation and Instruction Manual Table of Contents Introduction ........................9 1.1 Koehler’s Commitment to Our Customers ..................9 1.2 Recommended Resources and Publications ..................9 1.3 Instrument Specifications ........................9 Safety Information and Warnings ................10 Getting Started ......................
K18864 only) provide you with the best solutions. You can Optional depend on Koehler for a full range of accurate and Temperature reliable instrumentation as well as support for your Range: Ambient to -73°C (-100°F) laboratory testing programs.
K185-0-44 Bearing Holder address all of the safety problems associated with K18860-0-23 Sleever Trust Indicator the use of this equipment. It is the responsibility of K18854-Manual Temperature Torque any user of this equipment to investigate, Apparatus Operation and Instruction Manual...
12” of space between the back of that the carrier inspect the shipping container and the bath and the wall for airflow. Blocking the equipment. Do not return goods to Koehler without airflow will cause a malfunction to occur. written authorization.
2. Set Point Temperature Display. The ASTM D1478 Test Rig – Left side meter lower green LED display shows the set ASTM D4693 Test Rig – Right side meter point temperature of the controller. -12- K18854,55,64,65-Manual...
Page 14
This operation should be done temperature controller for the unit comes when installing a new unit, after replacing or pre-programmed from the Koehler factory. changing the bath medium type, or utilizing a Please do NOT attempt to re-program the...
Slide on the spring followed by chamber. the outer compression plate with the shoulder facing the hub. Slip on the washer and thread 3. Position the Test Rig Relative to the Load on the nut, but do not tighten. Cell: -14- K18854,55,64,65-Manual...
Test Rig: information on cleaning and storage of bearings and test rigs. One end of the resistor is inserted into Terminal 4 (black wire) and the other end is inserted into Terminal 6 (green wire). -15- K18854,55,64,65-Manual...
11 lbs. Each additional weight should again. The main power switch also functions as a register an additional 11 lbs. Adjust the span circuit breaker. screw to make any correction. -16- K18854,55,64,65-Manual...
Contactor, DPST, 30A, 240V personal injury or death. If you have any questions about maintaining your equipment, then please do 091-032-001 Relay, Solid State, 4-32 VDC, 20A not hesitate to contact the Koehler technical 275-103-037 Temp Safety Limit, 230V, RTD service department. 278-001-002...
Need help?
Do you have a question about the K18854 and is the answer not in the manual?
Questions and answers