Koehler K1798 Series Operation And Instruction Manual

Koehler K1798 Series Operation And Instruction Manual

Corrosion preventative properties apparatus

Advertisement

Quick Links

K1798X
Corrosion Preventative Properties
Apparatus
Operation and Instruction Manual
REV A
Koehler Instrument Company, Inc.
1595 Sycamore Avenue • Bohemia, New York 11716-1796 • USA
Toll Free: 1-800-878-9070 (US only) • Tel: +1 631 589 3800 • Fax: +1 631 589 3815
http://www.koehlerinstrument.com • e-mail: info@koehlerinstrument.com
Petroleum Testing & Analysis Instrumentation • Custom Design & Manufacturing

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the K1798 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Koehler K1798 Series

  • Page 1 Apparatus Operation and Instruction Manual REV A Koehler Instrument Company, Inc. 1595 Sycamore Avenue • Bohemia, New York 11716-1796 • USA Toll Free: 1-800-878-9070 (US only) • Tel: +1 631 589 3800 • Fax: +1 631 589 3815 http://www.koehlerinstrument.com • e-mail: info@koehlerinstrument.com...
  • Page 3 FTM 791-4012 This unit is tested before it leaves the factory, to ensure total functionality and compliance to the above specifications and ASTM standards. Test and inspection records are on file for verification. Jesse Kelly Application Engineer Koehler Instrument Company...
  • Page 5 K1798X Corrosion Preventative Properties Apparatus Operation and Instruction Manual K1798X-Manual...
  • Page 6 K1798X Corrosion Preventative Properties Apparatus Operation and Instruction Manual K1798X-Manual...
  • Page 7 Responsibility for Registration and Annual Reporting: Koehler will not sell directly to end users in the EU and so has no responsibility to register within each EU state and to make annual reports. Koehler declares that this responsibility is born by the importer who is the first level of the distribution chain and is subject to producer responsibility.
  • Page 8 K1798X Corrosion Preventative Properties Apparatus Operation and Instruction Manual All Koehler equipment has been placed on the market since 13th August 2005 and so Koehler is defined as a "new WEEE producer". As such we must provide information on refurbishment, treatment, and re-use.
  • Page 9: Table Of Contents

    K1798X Corrosion Preventative Properties Apparatus Operation and Instruction Manual Table of Contents 1 Introduction ........................6 1.1 Koehler’s Commitment to Our Customers ..................... 6 1.2 Recommended Resources and Publications ..................6 1.3 Instrument Specifications ........................6 2 Safety Information and Warnings ................7 3 Getting Started.......................
  • Page 10: Introduction

    Drive Motor Speed: 1750 RPM provide you with the best solutions. You can depend on Koehler for a full range of accurate and Dimensions reliable instrumentation as well as support for your (lxwxh,in.(cm)): 10x15x20 laboratory testing programs.
  • Page 11: Safety Information And Warnings

    K1798X Corrosion Preventative Properties Apparatus Operation and Instruction Manual 2 Safety Information and Warnings  WARNING: Safety glasses must be Safety Considerations. this worn at all times in the work areas equipment may involve hazardous materials and  Rings and jewelry must not be worn operations.
  • Page 12: Unpacking

    We will assist you with your claim, if requested. When submitting a claim for shipping damage, request that the carrier inspect the shipping container and equipment. Do not return goods to Koehler without written authorization. Setup Equipment Placement. Place the instrument on a firm, level table in an area with adequate ventilation or in a hood.
  • Page 13: Description

    K1798X Corrosion Preventative Properties Apparatus Operation and Instruction Manual 4 Description 5. Spindle/Thrust Loading Device. Spring loaded device to apply a precise load to the Instrument Descriptions test bearing while capable of spinning in conjunction with the drive motor (5). Equipped with an indexing pin for alignment with the hole located on the 1kg weight.
  • Page 14: Operation

    K1798X Corrosion Preventative Properties Apparatus Operation and Instruction Manual 5 Operation Standardization of Thrust Loading Device Preparation of Bearings 1. To standardize the thrust loading device a 1. Only bearings that have outer races and packed bearing must be prepared and rollers entirely free of corrosion should be installed into a bearing holder assembly.
  • Page 15: Grease Packing Procedure

    K1798X Corrosion Preventative Properties Apparatus Operation and Instruction Manual 5. Place the 3mm spacer (Figure 2, item 4) on top of this nut and bring the upper adjustment nut (Figure 3, item 9) down to the spacer. 6. Hold the upper adjustment nut in position, then remove the spacer and run the lower Figure 7.
  • Page 16: Bearing Holder Assembly Procedure

    K1798X Corrosion Preventative Properties Apparatus Operation and Instruction Manual 5. Remove the cylinder and plunger from the 2. Wearing gloves, hold the packed bearing bearing cup. Wearing gloves, remove the with the large inside diameter of the cup bearing cup and cone together as a unit facing down and insert the small diameter from the grease packer stand.
  • Page 17: Test Procedure

    K1798X Corrosion Preventative Properties Apparatus Operation and Instruction Manual Test Procedure WARNING: Apply pressure downwards slowly and smoothly. Do not apply pressure WARNING: Always use a safe working rapidly or in a jerky manner. posture (beware of hair catching). Stand erect, do not lean forward or place face near the rotating 4.
  • Page 18: Rating Procedure

    Each group of three bearings personal injury or death. If you have any questions is one test. about maintaining your equipment, then please do not hesitate to contact the Koehler technical service department. WARNING: Wait until the motor is fully spun...
  • Page 19: Wiring Diagrams

    K1798X Corrosion Preventative Properties Apparatus Operation and Instruction Manual 7 Wiring Diagrams 7.1 115V Unit Wiring (K17980) -15- K1798X-Manual...
  • Page 20: 220-240V Unit Wiring (K17989)

    K1798X Corrosion Preventative Properties Apparatus Operation and Instruction Manual 7.2 220-240V Unit Wiring (K17989) -16- K1798X-Manual...
  • Page 21: Service

    Goods must be returned freight prepaid. We, at Koehler, would like to thank you for your Returns will be subject to a restocking charge, the equipment purchase, which is protected by the application of which will depend upon the following warranty.
  • Page 22: Notes

    K1798X Corrosion Preventative Properties Apparatus Operation and Instruction Manual Notes -18- K1798X-Manual...

This manual is also suitable for:

K17980K17989