  • Page 1 K34700, K34701, K34702 Brookfield Viscosity Air Bath, BVS4000 service | innovation | technology REV K-A...
  • Page 2 BVS4000 Brookfield Viscosity Air Bath Operation and Instruction Manual - ii -...
  • Page 3 ERTIFICATE OF ONFORMANCE Brookfield Viscosity Air Bath, BVS4000 K34700, K34701, K34702 This certificate verifies that part numbers K34700, K34701, K34702, Brookfield Viscosity Air Baths, were manufactured in conformance with the applicable standards set forth in this certification. Specifications: ASTM D2983...
  • Page 4 BVS4000 Brookfield Viscosity Air Bath Operation and Instruction Manual - iv -...
  • Page 5 Responsibility for Registration and Annual Reporting: Koehler will not sell directly to end users in the EU and so has no responsibility to register within each EU state and to make annual reports. Koehler declares that this responsibility is born by the importer who is the first level of the distribution chain and is subject to producer responsibility.
  • Page 6 Recycling is free of charge. Shipping is the responsibility of the end users. Whether shipping to a distributor or to Koehler directly, safe, properly declared, and labeled packaging and shipping expenses are the sole responsibility of the end user.
  • Page 7: Table Of Contents

    BVS4000 Brookfield Viscosity Air Bath Operation and Instruction Manual Table of Contents 1. Introduction 1.1. Koehler’s Commitment to Our Customers 1.2. Recommended Resources and Publications 1.3. Instrument Specifications 2. Safety Information and Warnings 3. Getting Started 3.1. Packing List 3.2. Unpacking 3.3.
  • Page 8: Introduction

    Providing quality testing instrumentation and technical support services for research and testing laboratories has been our specialty for almost 100 years. At Koehler, the primary focus of our business is providing you with the full support of your laboratory testing needs. Our products are backed by our staff of technically knowledgeable, trained specialists who are experienced in both petroleum products testing and instrument service to better understand your requirements and provide you with the best solutions.
  • Page 9: Instrument Specifications

    The instructions for preparing the equipment assume that the user is aware of the contents of this document, which lists the warranty conditions and important precautions. 3.1. Packing List • K34700/K34701/K34702 BVS4000 Brookfield Viscosity Air Bath System • Test Cell Turntable Accessories (Must be purchased separately) •...
  • Page 10: Unpacking

    Leveling the Koehler Viscometer: It is essential that the viscometer be level for proper operation. A level is located on the connecting rod behind the viscometer. Use the leveling feet attached to the stand to properly level the viscometer.
  • Page 11: Descriptions

    Operation and Instruction Manual Power: Connect the line cords for both the Brookfield Viscosity Air Bath and the Koehler or Brookfield Rotational Viscometer (please see section 3.1 for part numbers) to a properly fused and grounded receptacle with the correct voltage as indicated in section 3 or on the information plate at the back of the unit.
  • Page 12: Temperature Controller Operation

    IMPORTANT NOTE: The digital temperature controller has been pre-programmed specifically for this instrument at the Koehler factory. Please do NOT attempt to re-program the controller as this may cause undesired operation and will void the product warranty. If assistance is required, please do not hesitate to contact the Koehler technical service department.
  • Page 13: Operation

    Disconnect power to the unit before servicing to avoid exposure to high voltages and/or temperatures which may result in personal injury or death. If you have any questions about maintaining your equipment, then please do not hesitate to contact the Koehler technical service department. 6.1. Routine Maintenance The BVS4000 series Brookfield Viscosity Bath requires little routine maintenance to provide many years of continuous service.
  • Page 14: Replacement Parts

    We, at Koehler, would like to thank you for your equipment purchase, which is protected by the following warranty. If within one (1) year from the date of receipt, but no longer than fifteen (15) months from the date of shipment, Koehler equipment fails to perform properly because of defects in materials or workmanship, Koehler Instrument Company, Inc.
  • Page 15 BVS4000 Brookfield Viscosity Air Bath Operation and Instruction Manual Notes - 9 -...
  • Page 16 BVS4000 Brookfield Viscosity Air Bath Operation and Instruction Manual Notes - 10 -...