INSTRUCTION MANUAL ECOSOFT COMMERCIAL RO SYSTEM (MO5000, MO10000)
To prevent injuries when working with the pump and pressurized pipes, the pressure in the pipes
must first be relieved.
After the maintenance, install all dismantled protective devices in place.
Unauthorized modifications or alterations to the design of reverse osmosis systems can adversely
affect the safety of people and installations and are therefore prohibited.

2.1 Operating hazards

Operating hazards include possible non-obvious dangers such as:
— Danger due to failure of the control system.
— Danger due to incorrect operator behavior.
1. Electrical shock.
The reverse osmosis system operates on an electrical voltage of 230 V (AC). Improper opening of
the electrical cabinet or damage to electrical wires can result in electric shock (life-threatening!).
Any installation work that requires opening the electrical cabinet or touching the connecting
cable, it is allowed to carry out powered down (switch off the circuit breaker and unplug the unit)!
If the reverse osmosis unit is wired in rather than plugged in, it must be fully disconnected from
the grid with a 2- pole circuit breaker that routes both live and neutral conductors.
(Power cable, connection terminals, and EMI filter must be installed before the main circuit
breaker to prevent electromagnetic interference)
2. Noise.
At a distance of 0.5 m from the unit, the measured noise level will not exceed 80 dB. In the case of
background noise up to 80 dB, the law does not provide for any mandatory measures to protect
hearing. However, in places where there are several sources of noise, the sound pressure level may
increase and in this case it is necessary to use hearing protection. Therefore, if there are several
devices in one room, it is recommended to additionally measure the noise level and inform the
staff about the use of personal hearing protection.
This manual is the intellectual property of Ecosoft. Copying and reprinting is prohibited. © 2021
Only original parts as well as Ecosoft components and consumables
may be used. In case of damage associated with the use of other spare parts,
as well as components or consumables, Ecosoft is not responsible!
Following all safety measures does not fully prevent the operating hazards.