Replacing Filter Cartridges

Filter cartridge life will vary with pool conditions such as bather load,
wind, dust, etc. You can expect an average cartridge life of three (3)
years under normal conditions.
To replace filter cartridges:
1. Follow Opening the Filter exactly (page 5).
2. Separate the Top Manifold (1) from the filter cartridges and lay
the manifold to the side. See Figure 13.
3. Carefully remove each cartridge separately.
4. Place the four replacement cartridges onto the support pipes in
the bottom of the tank.
5. Reinstall the Top Manifold onto the cartridges and verify the
O-Ring (2) is secured to the manifold. See Figure 13.
6. Follow Installing the Filter Lid and Clamp Ring exactly (page 6).