Dimensional Drawings
58.4 cm
15.5"
39.4 cm
21.5"
54.6 cm
Head Loss Comparison Curve
10
9
8
7
6
5
4
3
2
1
0
0
20
40
Recommended Flow Rates
Filter Area
Model #
(Sq. Ft.)
C420
420
C520
520
C620
620
Note: Actual system flow will depend on plumbing size and other system components.
* Required Clearance to remove filter cartridges and lid.
DIM "A"
23"
Head Loss Curves
60
80
100
Flow Rate (gpm)
Vertical
Flow Rate
Clearance*
(GPM)
65 in.
150
80 in.
180
80 in.
180
22.5"
57.2 cm
23.5"
56.7 cm
120
140
160
180
Turnover Capacity (Gallons)
8 Hours
10 Hours
12 Hours
72,000
90,000
108,000
86,400
108,000
129,600
86,400
108,000
129,600
XF®
FULLFLO
C-SERIES Cartridge Filter Installation and User' s Guide
TECHNICAL DATA
MODEL
DIM "A"
C420
42.6" (108.2 cm)
C520
55.6" (141.2 cm)
C620
55.6" (141.2 cm)
200
13