This device has been tested in accordance with IEC60825-1 3rd ed., 2014., and has been certified to be under the limits of a Class 1 Laser device. Wavelength 650 nm laser radiation. To reduce the risk of injury or equipment damage, observe the following precautions when you install the Cognex product:...
Symbols Symbols The following symbols indicate safety precautions and supplemental information: WARNING: This symbol indicates a hazard that could cause death, serious personal injury or electrical shock. CAUTION: This symbol indicates a hazard that could result in property damage. Note: This symbol indicates additional information about a subject. Tip: This symbol indicates suggestions and shortcuts that might not otherwise be apparent.
Table of Contents Table of Contents Legal Notices Precautions Symbols Table of Contents Getting Started About High Speed Steerable Mirror Hardware Compatibility and Common Kits Accessories Recommended Lighting Accessories Setting Up Your DataMan 470 Reader Dimensions Field of View 1-Axis Field of View 2-Axis Field of View Scan Pattern Using Your High Speed Steerable Mirror...
Getting Started Getting Started This section provides general information about theDataMan 470 series reader with High Speed Steerable Mirror. For more information on the DataMan 470 reader, please refer to the DataMan 470 Series Reference Manual. About High Speed Steerable Mirror WARNING: Do not detach the High Speed Steerable Mirror.
Accessories You can purchase the following components separately. Note: For a list of options and accessories, contact your Cognex sales representative. Note: The HSSM is compatible with all cables, brackets, and external lighting of the DataMan 470. For general DataMan 470 accessories, please refer to the DataMan 470 Series Reference Manual.
Page 9
Getting Started Dual lights for 2-axis, wide FoV applications: The accessories are available with the following product specifications: Accessory Product ID Image 300 mm bar light, wide projection IVSL-YLW2X-625- 800 mm bar light, wide projection IVSL-LX800-625- 1 m bar light IVSL-DMBS6-625 Linear Polarizers for HSSM (includes both vertical and horizontal DM470-HSSM-LP...
Setting Up Your DataMan 470 Reader Setting Up Your DataMan 470 Reader Note: For information about mounting the reader, setting the focus, and connecting cables, refer to the DataMan 470 Series Reference Manual . Dimensions Observe the following dimensions when installing the reader.
The following field of view projections represent the approximate 1-Axis field of view achievable for 1D and 2D barcodes. Field of view coverage for 1D codes (3 and 5 MP) Reader Lens Module Size (mm) Max Working Distance (mm) Coverage (mm) Coverage (mm) DM474 16mm 0.254 (10 mil) 0.339 (13 mil) 1100 1225 0.508 (20 mil) 1670...
Setting Up Your DataMan 470 Reader Scan Pattern Typical use cases of the High Speed Steerable Mirror include the following: 1-Axis Mirror Movement for Moving Targets Inbound pallet side scanning Conveyor scanning 2-Axis Mirror Movement for Stationary Targets PCB scanning Product aggregation Manual product ID (PID)
To configure a reader with High Speed Steerable Mirror, install the DataMan Setup Tool software on a networked PC. For more information, see the DataMan support site, http://www.cognex.com/support/dataman. 1. Check the DataMan Release Notes for a full list of system requirements.
Using Your High Speed Steerable Mirror DataMan Control Commands Mirror paths and positions are manually programmed on the device through the use of DataMan Control Commands (DMCC) via Telnet or Serial interface. For more information on DMCC communications, please refer to the DataMan Communications and Programming Guide.
Page 18
Using Your High Speed Steerable Mirror Name Set/Get Args Range Meaning Description MIRROR.ANGLE- SET|GET uint8 [0-63] SET MIRROR. Get/set the stored angle values corresponding POSITION index to the given path position index. ANGLE-POSITION 2 float 10.5 10.5 For single axis motion, α or β may be expanded α...
Specifications Specifications The following sections list general specifications for the reader. Reader Specification Specification DM474 Variant DM475 Variant Weight 718 g Power 24 VDC ±10% 24 VDC ±10%, 1.5 A maximum Power Consumption Supplied by LPS or NEC class 2 only Trigger and Tune Yes;...
Cleaning and Maintenance Cleaning and Maintenance Cleaning the Housing To clean the outside of the reader housing, use a small amount of mild detergent cleaner or isopropyl alcohol on a cleaning cloth. Do not pour the cleaner directly onto the reader housing. CAUTION: Do not attempt to clean any DataMan product with harsh or corrosive solvents, including lye, methyl ethyl ketone (MEK) or gasoline.
This device has been tested in accordance with IEC60825-1 3rd ed., 2014., and has been certified to be under the limits of a Class 1 Laser device. Wavelength 650 nm laser radiation. Note: For the most current CE declaration and regulatory conformity information, see the Cognex support site: cognex.com/support.
Regulations and Conformity For European Community Users Cognex complies with Directive 2012/19/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 4 July 2012 on waste electrical and electronic equipment (WEEE). This product has required the extraction and use of natural resources for its production. It may contain hazardous substances that could impact health and the environment, if not properly disposed.
Need help?
Do you have a question about the DM474 and is the answer not in the manual?
Questions and answers