Parts
80cc-160cc Pumps
148
149
107
101
103
133
135
134
146
119
3
9
1.
Lubricate seals, o-rings, lead-in's and moving parts with
grease.
2
Apply one stripe of removable strength anaerobic sealant on
threads.
Specification sheets and Graco testing indicate that
anaerobic sealant requires three days to fully cure. Failure
to allow three days for full cure may result in damage to
the equipment from parts coming loose during operation.
If faster cure time is required, warm components to 104° F
(40° C) for 6 hours.
3
Torque to 50-ft-lbs (67.5 N•m).
5
Torque tie bolts (105) in star pattern ( F
ft-lbs (13.5 N•m). Then torque again to 50 ft-lbs (67.5 N•m).
Finally torque to 200 ft-lbs (271 N•m)
6
Torque to 200 ft-lbs. (271 N•m).
20
150
15
102
101
115
147
145
125
14
126
8
10
118
8
NOTICE
. 26 page 17) to 10
IG
9
13
108
104
102
124
117
11
12
112
12
120
7
See Piston Retainer Torque Specifications table on page 15
for torque specification.
8
Must be pressed straight into housing.
9
Apply anti-seize lubricant to threads.
10
Ensure spring side of one throat seal (126) faces throat
cartridge (118) and spring side of other seal faces throat
retainer (119)..
11
Ensure spring side of one piston seal (117) springs face
displacement rod (115) and piston bearing retainer (116).
12
Fully assemble u-cups (17) and bearing (16) onto
displacement rod (15) before tightening piston retainer (14).
13
Torque to 70 ft-lbs. (95 N•m).
14
Not used on 160cc pump. .
15
Used on 160cc pump only.
113
108
112
111
110
109
112
111
110
109
108
2
106
114
7
105
5