Error Message
"Invalid device Manager Service name or port."
"No task list file found. Task unchanged."
"Noise sampling procedure failed."
"Noise sampling procedure timed out."
"Operator load failed."
"Power-off error."
"Self test mode set, but no script file found."
"Software error while changing task. Task
unchanged."
"Task load failed."
A700x Product Guide
Solution
1. Reload the task.
2. Turn the device off and then turn it back on
again.
3. Reboot the device.
4. Reload VoiceClient.
1. Sample noise again.
2. Go to a quieter location and perform
another noise sample.
3. Try using another headset and perform the
noise sample.
NOTE
If this solves the problem, the first
headset might be damaged.
1. Sample noise again.
2. Reboot the device.
1. Go to an area of known good coverage.
2. Turn the device off and then turn it back on
again.
3. Reboot the device.
4. Reload VoiceClient.
1. Power on the device.
2. Reboot the device.
Edit the task configuration file, taskname.vcf, and
change the line selftest=1 to selftest=0.
1. Go to an area of known good coverage.
2. Turn the device off and then turn it back on
again.
3. Reload the task.
4. Reboot the device.
5. Reload VoiceClient.
1. Go to an area of known good coverage.
2. Turn the device off and then turn it back on
again.
3. Reload the task.
4. Reboot the device.