Technical Data - Graco 237-004 Instructions-Parts List Manual

30:1 ratio bulldog pump
Table of Contents

Advertisement

Maximum fluid working pressure
Air input pressure operating range
Ratio
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pump cycles per 1 gallon (3.8 liters)
Maximum recommended pump speed for continuous operation
Maximum flow
Air consumption
Air inlet
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fluid outlet
Weight
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wetted parts
KEY: Fluid Outlet Pressure – Black Curves
Air Consumption – Gray Curves
cycles/min
psi
bar
210
MPa
21.0
100 psi (0.7 MPa, 7 bar)
air pressure
175
17.5
140
14.0
105
10.5
40 psi (0.3 MPa, 3 bar)
air pressure
70
7.0
35
3.5
gpm
liters/min
To find Fluid Outlet Pressure (bar/psi/MPa) at a specific fluid flow
(lpm/gpm) and operating air pressure (bar/psi/MPa):
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with selected fluid outlet
pressure curve (black). Follow left to scale to read fluid outlet
pressure.

Technical Data

. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
at 1 gpm (3.8 liters/min) at 100 psi (0.7 MPa, 7 bar) air pressure
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
40
20
70 psi (0.49 MPa, 4.9 bar)
air pressure
3.8
7.6
FLUID FLOW (TEST FLUID: NO. 10 WEIGHT OIL)
3000 psi (21.0 MPa, 210 bar)
40–100 psi (0.28–0.7 MPa, 2.8–7 bar)
. . . . . . . . .
60 cycles per min
3 gpm (11.34 liter/min)
approx. 34 scfm (0.95 m /min)
approx. 75 lb (34 kg)
See displacement pump manual 307–862
60
80
100 psi (0.7 MPa, 7 bar)
air pressure
70 psi (0.49 MPa, 4.9 bar)
air pressure
40 psi (0.3 MPa, 3 bar)
air pressure
11.4
15.2
To find Pump Air Consumption (m /min or scfm) at a specific fluid
flow (lpm/gpm) and air pressure (bar/psi):
1. Locate desired flow along bottom of chart.
2. Read vertical line up to intersection with selected air consumption
curve (gray). Follow right to scale to read air consumption.
30:1
20
3/4 npt(f)
3/4 npt(f)
scfm
m /
min
100
2.80
80
2.240
60
1.680
40
1.120
20
0.56
19.0
306–694

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

221-068217-579237-067

Table of Contents