Dial Timer Control Panel Operation

1. Cooking Operations – Dial Timer Control Panel
Figure 4-3
Mechanical Timer
Control Panel
1. TIMER – This dial sets the operating time from 0 to 60
minutes.
Turn the dial clockwise until it points to the
required number of minutes.
When it reaches 0, an alarm sounds for 3
seconds.
2. TIMED/MANUAL Switch – The TIMED/MANUAL
switch selects the Manual or Timed operating mode.
Pressing the MANUAL (bottom) end of the switch
selects the manual mode.
Pressing the TIMED (top) end of the switch
selects the timed mode.
3. ON/OFF Switch – The ON/OFF switch controls
electric power to the control panel.
Pressing the ON (top) end of the switch energizes
the steamer control panel. The red indicator on
the switch lights, and all the safety controls
become active.
Pressing the OFF (bottom) end of the ON/OFF
switch turns the steamer control panel OFF. The
red indicator goes out, all control circuits are
deactivated, and the high limit circuit is reset if it
had been activated.
4. Heat On Indicator Light – When the amber indicator
light is on, the heating elements are ON.
5. Add Water Indicator Light – When the water level
drops below the water level sensor the green
indicator light comes ON, an alarm sounds
continuously and the heating elements are turned
OFF.
6. Hi Limit Reset Light – If the high limit temperature is
reached, the red indicator light comes ON, an alarm
sounds, the heating elements are turned OFF and the
control panel is de-energizes. To reset the system,
turn the ON/OFF switch OFF for 5 minutes and then
back ON.