Putting Into Operation; Equipping The Mig Gun Neck Abimig At Equipping The Mig Gun Neck Abimig Wt - Abicor Binzel FreedomDrive Abimig AT355 Operating Instructions Manual

Push-pull mig/mag
Table of Contents

Advertisement

4

Putting into operation

4
Putting into operation
!
DANGER
Risk of injury due to unexpected start-up.
For the entire duration of maintenance, servicing, dismounting and repair work,
the following instructions must be adhered to:
• Switch off the power supply.
• Close off the compressed gas supply.
• Pull the mains plug.
4.1
Equipping the MIG gun neck ABIMIG AT
1
1
Gas nozzle
2
Contact tip
Fig. 1
Equipping the ABIMIG AT MIG gun neck
1 Screw, tip holder (3) and contact tip (2) onto the gun neck (5)
The insulator (4) protects otherwise exposed areas.
2 Screw the gas nozzle (1) onto the tip holder (3).
4.2
Equipping the MIG gun neck ABIMIG WT
1
1
Gas nozzle
2
Spatter Protector
Fig. 2
Equipping the ABIMIG WT MIG gun neck
1 Screw the replaceable tip adapter (4) onto the gun neck (5)
and tighten the tip adaptor (4) using the supplied wrench
2 Screw the contact tip (3) into the tip adaptor (4)
3 Tighten the contact tip (3) with the supplied wrench
4 Insert the spatter protector (2) into the gas nozzle (1) from the
back prior to screwing the gas nozzle (1) onto the gun neck (5)
6
2
3
Tip adapter
4
Insulator
2
3
3
Contact tip
4
Tip adapter
3
5
MIG gun neck
4
5
MIG gun neck
FreedomDrive
4
5
5