Summary of Contents for Extraflame SHARON PLUS

  • Page 1 Manual sharon plus MADE ITALY design & production 004280809 - Rev.000...
  • Page 2 APPLY TECHNICAL DATA LABEL ENGLISH...
  • Page 3: Table Of Contents

    PREPARATIONS FOR MAINTENANCE ....................................8 HErMEtIcaLLy SEaLEd INStaLLatIoN ............................10 COMbuSTION AIR ............................................10 FuMES EXHAuST SYSTEM ........................................10 dEtaILS of SHaroN PLuS ................................11 StoVE PoSItIoNING ..................................12 MaNdatory WaLL MouNt ................................12 coMBuStIoN aIr ....................................13 fLuE GaS outLEt ....................................13 Hot aIr ductING ....................................
  • Page 4 it - AttENZiONE tASSAtiVO PrimA di mOVimENtArE lA StufA tOgliErE il riVEStimENtO iNdicAtO PEr EVitArE dANNi. EN - WArNiNg BEfOrE hANdliNg thE StOVE, thE cOVEriNg iNdicAtEd muSt BE rEmOVEd tO AVOid dAmAgE. fr - AttENtiON imPÉrAtifAVANt dE dÉPlAcEr lE POêlE, rEtirEr lE rEVêtEmENt iNdiquÉ POur ÉVitEr tOut dOmmAgE.
  • Page 5: English

    We thank you for having chosen our company; our product is a great heating solution developed from the most advanced technology with top quality machining and modern design, aimed at making you enjoy the fantastic sensation that the heat of a flame gives, in complete safety. Warnings This instructions manual is an integral part of the product: make sure that it always accompanies the appliance, even if transferred to another owner...
  • Page 6 RECEIVED INSTRUCTIONS ON SAFE USE OF THE APPLIANCE AND THAT THEY UNDERSTAND THE INHERENT DANGERS. Š THE GENERATOR MUST NOT BE USED BY PERSONS (INCLUDING CHILDREN) WITH REDUCED PHYSICAL, SENSORY AND MENTAL CAPACITIES OR WHO ARE UNSKILLED PERSONS, UNLESS THEY ARE SUPERVISED AND TRAINED REGARDING USE OF THE APPLIANCE BY A PERSON RESPONSIBLE FOR THEIR SAFETY.
  • Page 7: Routine Maintenance

    (STRONG WIND, FREEzING) SAFETY SYSTEMS MAY INTERVENE THAT SWITCH THE GENERATOR OFF. IF THIS OCCURS, CONTACT THE TECHNICAL AFTER-SALES SERVICE AND ALWAYS DISABLE THE SAFETY SYSTEMS. Š IN THE EVENT THE FLUE CATCHES FIRE, USE SUITABLE SYSTEMS FOR SUFFOCATING THE FLAMES OR REQUEST HELP FROM THE FIRE BRIGADE.
  • Page 8: Installation

    InstallatIOn general The flue gas exhaust and hydraulic connections must be carried out by qualified personnel who must issue installation conformity documentation compliant with national standards. The installer must provide the owner or person acting for him, according to the legislation in force, with the declaration of conformity, supplied with: 1) the use and maintenance manual of the appliance and of the system components (such as for example, the smoke ducts, chimney, etc.);...
  • Page 9 In the presence of type B gas appliances with intermittent operation not intended for heating, they must have their own aeration and/or ventilation opening. The air inlets must meet the following requirements: Š they must be protected with grids, metal mesh, etc., but without reducing the net useful section; Š...
  • Page 10: Hermetically Sealed Installation

    Hermetically sealed installation The generator is a fully sealed product with respect to the environment in which it is installed. This means that it is ideal for passive houses because it does not take air in from within the house. combustion air To ensure the stove remains hermetically sealed, the connection pipe for the combustion air must be directly connected to the exterior, using special pipes and sealed connectors.
  • Page 11: Details Of Sharon Plus

    DEtaILs OF sHarON PLUs Radio/emergency board Rear ducting Serial input Combustion air inlet Access to combustion chamber and ash drawer 230 V power supply FUSE Additional thermostat input (TA) On/Off Room air outlet Spacer Pellet hopper pressurised closure Rear flue gas outlet...
  • Page 12: Stove Positioning

    stOVE POsItIONING To ensure the stove works correctly, it should always be positioned so that it is perfectly level, using a spirit level. MaNDatOry waLL MOUNt On the back of the machine, there are spacers (A) which determine the minimum distance to maintain from any rear support. The spacers must not be removed.
  • Page 13: Combustion Air

    cOMbUstION aIr The generator has an inlet for drawing combustion air directly from the room or from outside the building. FLUE Gas OUtLEt The flue gas outlet is mounted on the top of the generator in the factory. The flue gas outlet can be moved to the rear by following the instructions in the chapter “REAR FLUE GAS OUTLET ASSEMBLY” THE CONvErsION OF THE uppEr FLuE GAs OuTLET MusT BE CArrIED OuT BY QuALIFIED pErsONNEL AND/Or THE MANuFACTurEr’s TECHNICIANs HOt aIr DUctING...
  • Page 14: Operation In Air Ducting With Thermostat Or Probe (Optional)

    OPEratION IN aIr DUctING wItH tHErMOstat Or PrObE (OPtIONaL) The stove is fitted with an independent motor for ducting. The connection of an external thermostat or temperature probe (NTC 10K) in the input, located in the rear part of the stove, makes it possible to control the air ducting motor independently of the stove. Suffice it to connect the thermostat/temperature probe and set the desired temperature.
  • Page 15: Fuse

    FUsE If the stove is not powered, have the condition of the fuse checked by a qualified technician. NOtEs FOr cOrrEct OPEratION External door Pellet hopper lid The following indications must be respected for correct pellet stove operation: Both during stove operation and when it is not used, all hatches (pellet hopper, door, ash drawer) must remain closed at all times.
  • Page 16: Pellets And Loading

    Pellets and loading Pellets are made by subjecting wood shavings i.e. the rejects of pure unpainted wood from sawmills, carpentry products and products from other activities connected to wood working and transformation, to very high pressures. This type of fuel is fully ecological as no glues are used for its compaction. In fact, pellet compactness is guaranteed over time by a natural substance found in wood: lignite.
  • Page 17: Radio/Emergency Card

    Radio/emeRgency caRd The stove is fitted with an emergency radio card which allows for basic control of the stove in the event of a fault or if the remote control is malfunctioning. The functions that can be managed from the emergency card are: On/Off stove.
  • Page 18: Radio Control

    radIO cOntrOl cOnFIGUratIOn RAdIo conTRol devIce codIng pRoceduRe: 1. disconnect the power supply to the stove. 2. press the keys at the same time until the UNIT selection screen appears. 3. using keys select the new UNIT' . 4. power the stove. Within 10 seconds (the led on the emergency module will flash) confirm the selected unit by pressing on the radio control device.
  • Page 19: Radio Control Device Features

    radIO cOntrOl devIce FeatUres Š The radio control device is fitted with an lcd backlit display. The display remains lit for 5 seconds. After a certain period of time, in order to minimise battery consumption, the display turns off (sleep mode). Š...
  • Page 20: Display

    dIsplay ScREEn in oPERation ScREEn in oPERation STAnd BY active chrono active Battery low power 1-5^ Time Air ducting active Temperature detected in room Tangential fan active Set room temperature display text Tangential fan active in coMFoRT mode ScREEn WitH EXtERnaL tHERMoStat connEctED to tHE tERMinaL “ta” Time Indicates contact of the additional outdoor...
  • Page 21: General Menu

    General menU Function Function Scroll through parameters Back - exit key Modify settings Ignition - switch-off key Access menu key MoDES FRont aiR aiR DuctinG *aiR ZonE contRoL EaSy SEtuP cHRono EnaBLinG PRG1 PRG2 SEttinGS DatE-tiME PRG3 LanGuaGE PRG4 DiSPLay StanD By DELta-t FiRSt LoaD...
  • Page 22: First Ignition Settings

    FIrst IGnItIOn settInGs once the power cable at the back of the generator has been connected, move the switch to (I). This switch powers the generator board. The generator remains off and an initial screen appears on the panel, displaying oFF . DatE-tiME This menu allows the date and time to be set.
  • Page 23: Operation And Logic

    OperatIOn and lOGIc IGnItIOn once the previously listed points have been checked, press key for three seconds to ignite the stove. during ignition, the stove will check for a flame for a period of 15 minutes. once the control temperature has been reached, the stove interrupts the ignition phase and switches to pRepARATIon.
  • Page 24: Modes

    mOdes This menu allows you to set the machine operation logic. Range: (AuToMATIc, SelF conTRol) If AuToMATIc mode is selected, the stove power will be automatically adjusted to reach the set temperature without exceeding it. this function improves the experience of using the generator in terms of consumption, thermal and acoustic comfort and the reduction in the need for cleaning and maintenance.
  • Page 25: Chrono

    chrOnO This function allows stove ignition and switch-off to be automatically programmed. The factory setting for cHRono is off. The chrono allows the programming of 4 time slots per day, which can be used every day of the week. For each time slot, it is possible to set ignition and switch-off times, specific days of application, desired temperature and set power.
  • Page 26 EXaMPLE oF cHRono oVERLaPPinG tiMES/SLotS tiME SLot 02:00 08:00 16:30 23:00 poWeR 02:00 08:00 16:30 23:00 SeT TeMpeRATuRe 22° 18° 02:00 08:00 16:30 23:00 Start 02:00 Time slot 1 power 3 - set temp 22°c Stop 23:00 Start 08:00 Time slot 2 power 1 - set temp 18°c Stop 16:30 Stove operation...
  • Page 27: Settings

    settInGs Š dATe-TIMe Š lAnguAge See cHApTeR: FIRST IgnITIon SeTTIngS. Š SeT degReeS dIsplay The "dISplAY" menu allows: Š Adjustment of display contrast. Š Activation/deactivation of backlight. Š enabling/disabling of acoustic signal. Š Setting of the timer to turn off the display backlight. Š...
  • Page 28: Delta-T

    There are no physical keys connected to the Wi-Fi module, enABlIng and ReSeT are performed using the remote control via the boiler card. The configuration must be entered using the Total control 2.0 App. For instructions, consult the website: https://www.lanordica-extraflame.com/sites/default/files/documenti_temp/004281060-000_istr.app_total_control_2.0.pdf Š EnaBLinG The integrated Wi-Fi can be enabled and disabled.
  • Page 29: Operation And Solutions

    To set: OK > SeTTINgS > WI-FI > INFO - MAc: unique identification code of the Wi-Fi device - code: numeric code required for connection with the extraflame server - RSSI: Received signal strength, when the Wi-Fi is correctly connected to an access point The rSSI value is expressed in decibels (db) as a negative number which is typically in the range between -60db (excellent signal) and -85db (very poor signal).
  • Page 30: Additional Functions

    depressUre nOtIce It allows you to activate the buzzer for acoustic warnings if the door or the hopper are open. Please note: activation can reduce battery life by 30%. the battery life depends on the usage To set: OK > SeTTINgS > DepreSSUre NOTICe addItIOnal FUnctIOns addItIOnal thermOstat InstallatIOn (OptIOnal) The stove can control the room temperature through an additional thermostat (optional).
  • Page 31: Cleaning And Maintenance

    TO FIND OUT WHERE YOUR NEAREST SERVICE CENTRE IS, CONTACT YOUR DEALER OR VISIT THE WEBSITE: WWW.LANORDICA-EXTRAFLAME.COM CLEANING AND MAINTENANCE ALWAYS FOLLOW THE INSTRUCTIONS IN COMPLETE SAFETY! Š Make sure that the power supply cable plug is disconnected, as the generator may have been programmed to turn on.
  • Page 32 EXTERNAL DOOR-EXTERNAL GLASS Š Only clean the external glass (door) when cold! bURN POT AND COMbUSTION CHAMbER Š Remove the ash conveyor (1) completely, emptying any ash resides into the burn pot below. Š Remove the burn pot (2) and empty out any ash residues.
  • Page 33: Routine Maintenance Performed By Qualified Technicians

    It is also advisable to disconnect the generator from the electrical power supply and, for greater safety especially in the presence of children, remove the power cord. Routine maintenance must be performed at least once a year. TO FIND OUT WHERE YOUR NEAREST SERVICE CENTRE IS, CONTACT YOUR DEALER OR VISIT THE WEBSITE: WWW.LANORDICA-EXTRAFLAME.COM ENGLISH...
  • Page 34 ROUTINE MAINTENANCE THE IMAGES ARE FOR ILLUSTRATIVE PURPOSES. SHARON PLUS SHARON PLUS Fumes motor (disassembly and cleaning and fumes pipe and "T"), new silicone in the provided points Gaskets, pellet hopper, inspections, ash drawer and door (replace and apply silicone where indicated) Combustion chamber and heat exchanger (full cleaning) including ignition plug pipe Hopper (complete emptying and cleaning) and check gasket.
  • Page 35: Displays

    Displays Display Reason Generator off sTaRT The start-up phase is in progress pelleT loaDinG Continuous pellet loading is in progress during the ignition phase iGniTion The ignition phase is in progress pRepaRaTion The preparation phase is in progress WoRk The normal work phase is in progress MoDulaTion The generator is working at minimum final cleaninG...
  • Page 36: Disposal

    Disposal InformatIon for management of electrIc and electronIc applIance waste contaInIng batterIes or accumulators This symbol, which is used on the product, batteries, accumulators or on the packaging or documents, means that at the end of its useful life, this product, the batteries and the accumulators included must not be collected, recycled or disposed of together with domestic waste. Improper management of electric or electronic waste or batteries or accumulators can lead to the leakage of hazardous substances contained in the product.
  • Page 37 ENGLISH...
  • Page 38 ENGLISH...
  • Page 39 ENGLISH...
  • Page 40 ExtraflamE S.p.a. Via Dell’Artigianato, 12 36030 - MONTECCHIO PRECALCINO (VI) - ITALY   +39.0445.865911 -  +39.0445.865912 -  info@extraflame.it - www.lanordica-extraflame.com MADE ITALY design & production TO FIND THE SERVICE CENTRE NEAREST TO YOU CONTACT YOUR DEALER OR CONSULT THE SITE WWW.LANORDICA-EXTRAFLAME.COM...

This manual is also suitable for:

Sharon plus petraSharon plus crystal

Table of Contents