Lotus FQ-4G Installation And Operating Instructions Manual

Lotus FQ-4G Installation And Operating Instructions Manual

Professional gas fryer

Advertisement

Quick Links

Installation and operating instructions
PROFESSIONAL GAS FRYER
FQ-4G FQ-6G FP-6G FQM-4G
Model LIBR.ISTR.FQ65G
Code 563004800
Review 1
Edition date 15/05/2019
Language English
LOTUS S.p.A.
Via Calmaor, 46
31020 San Vendemiano
+39 0438 778020
+39 0438 778277
Translation of the original instructions

Advertisement

Table of Contents
loading

Summary of Contents for Lotus FQ-4G

  • Page 1 Installation and operating instructions PROFESSIONAL GAS FRYER FQ-4G FQ-6G FP-6G FQM-4G Model LIBR.ISTR.FQ65G Code 563004800 Review 1 Edition date 15/05/2019 Language English LOTUS S.p.A. Via Calmaor, 46 31020 San Vendemiano +39 0438 778020 +39 0438 778277 Translation of the original instructions...
  • Page 2: Table Of Contents

    Contents Contents INTRODUCTION ......................... Installation drawing ........................Components..........................GENERAL INFORMATION......................Declaration of compliance......................Technical data table ........................INSTALLATION........................... Delivery checks ..........................Removing the packaging ......................Mechanical installation ......................... Electrical/gas connections ......................BURNERS TECHNICAL DATA TABLE (ITGB)................Burners technical data table ......................INSTRUCTIONS FOR USE......................
  • Page 3: Introduction

    INTRODUCTION 1 INTRODUCTION Installation drawing FIG. 1 FQ-4.. FQ-6.. FP-6.. A Data Plate C Gas connection   Translation of the original instructions...
  • Page 4 INTRODUCTION FIG. 2 FQM-4.. A Data Plate C Gas connection   Translation of the original instructions...
  • Page 5: Components

    INTRODUCTION Components FIG. A 1 Gas inlet 2 Ramp 3 Injector 4 Burner 5 Safety thermostat 6 Air adjustment 7 Knob 8 Extends drainage 9 Pilot 10 Ignition spark plug 11 Oil drain 12 Piezoelectric 13 Valve Translation of the original instructions...
  • Page 6 INTRODUCTION FIG. C A Piezoelectric   FIG. D 1 Bracket 2 Pilot light nozzle 3 Extends drainage 4 Ignition spark plug   FIG. E Burner air adjustment   Translation of the original instructions...
  • Page 7: General Information

    GENERAL INFORMATION 2 GENERAL INFORMATION Declaration of compliance The manufacturer declares that the appliances comply with the requirements of the regulation GAR 2016/426 for the gas part and directive 2014/30/EU,2014/35/EU for the electrical part. Installation must be performed in compliance with current regulations, especially with regard to ventilation of the premises and the exhaust gas evacuation system.
  • Page 8: Technical Data Table

    GENERAL INFORMATION Technical data table Technical data table FQ S65G RATED GAS FITTING TANK CAPACITY MODEL DIMENSIONS TOTAL GAS ISO 7-1 (lt) FLOW (kW) FQ - 4G 40x65x29h R ½GM FQ - 6G 60x65x29h R ½GM 10 + 10 FP - 6G 60x65x29h R ½GM FQM - 4G...
  • Page 9: Installation

    INSTALLATION 3 INSTALLATION Delivery checks On delivery, it is important to check the following:   · External conditions of the packaging · The general status of the equipment · The conformity of the model with the information in the technical data plate and the instruction manual ·...
  • Page 10 INSTALLATION Installation operations, any conversion to other types of gas and start-up must only be   performed by qualified personnel, in accordance with current regulations.   Gas systems, electrical connections and premises where the appliances are installed must comply with current regulations in the country of installation;...
  • Page 11 INSTALLATION   For burners equipped with air adjustment, set the adjustable bushing and lock it with a screw. The "Burner technical data" table shows approximate values for the "h" parameter (primary air). The primary air flow volume must be adjusted to avoid a flame cut-off when the burner is cold and a flame blowback when the burner is hot.
  • Page 12 INSTALLATION Forced evacuation (fig.4) The gas supply to the appliance must be directly servo-controlled by the forced evacuation system and must stop if the flow rate drops below the values indicated in point 4.3 of the UNI-CIG 8723 standard. Resetting the gas supply to the appliance must be possible only by hand.
  • Page 13: Burners Technical Data Table (Itgb)

    12.68 kWh/KG 12.87 kWh/KG 9.45 kWh/m3st.   BUTANE PROPANE METHANE H 30 mbar 37 mbar 20 mbar FQ-4G       Burner 7 kW Burner injector 1/100 mm 2 x 98 2 x 98 2 x 153 Pilot injector 1/100 mm Consumption kg/h 0.545...
  • Page 14: Instructions For Use

    INSTRUCTIONS FOR USE 5 INSTRUCTIONS FOR USE General information This appliance must only be used for its expressly intended purpose for cooking or heating food. Any other use is considered improper. The appliance is also intended for industrial use and must only be used by personnel trained for use and aware of the risks that the hot element entails.
  • Page 15: Switching The Appliance Off

    INSTRUCTIONS FOR USE · Turn the graduated valve knob to the star position . In this position only the pilot flame remains lit Switching the appliance off · Press and turn the knob to position "0". This control blocks the gas supply to both the main burner and the pilot burner  ...
  • Page 16: Top Appliances Bowl Emptying

    INSTRUCTIONS FOR USE Top appliances bowl emptying · The user is required to have a suitable recipient for emptying the water/oil · Insert the drain tube as shown on the drawing, position the container · Push the safety device upwards against the involuntary openings (A) and move the lever (B)  ...
  • Page 17: Maintenance

    MAINTENANCE 6 MAINTENANCE Routine When using the appliance over time, it is essential to perform regular maintenance to ensure safe operation. We therefore recommend stipulating a service contract.   Caution Maintenance must only be performed by specialist personnel in compliance with current  ...
  • Page 18: Spare Parts

    MAINTENANCE · Replace the nozzle with the appropriate version and make sure that, after ignition, the flame correctly touches the tip of the thermocouple   Warning After conversion to another type of gas, update the technical data plate to indicate the type of  ...
  • Page 19: Cleaning

    CLEANING 7 CLEANING Routine cleaning Caution The use of flammable fluids to clean the appliance is forbidden     To ensure hygiene and the durability of the appliance, perform external cleaning on a regular basis, taking care not to damage the cables and the electrical connections. Before starting cleaning, disconnect the appliance from the power supply.