TABLE "B" LOGICS
Any modi cation of parameters/logics must be con rmed by pressing S2 > 5s
DIP
Logic
Transmitter
1
programming
2
BAR / 8K2
Photocell input
3
check
4
Edge input check
Photocells
5
during closing
Safety edge
6
input operation
7
Fast closing
Residential /
apartment
8
building
operation
26 -
SHYRA-F
INSTALLATION MANUAL
Cross out
Default
Description
setting used
Enables wireless memorizing of transmitters:
1- Press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has already
been memorized in standard mode via the radio menu.
2- Press within 10 sec. the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
ON
The receiver exits programming mode after 10 sec.: you can use this time to enter other new
transmitters.
ON
This mode does not require access to the control panel.
IMPORTANT: Enables the automatic addition of new transmitters, clones and replays.
Disables wireless memorizing of transmitters and automatic addition of clones.
OFF
Transmitters are memorized only using the relevant Radio menu or automatically with replays.
IMPORTANT: Disables the automatic addition of new transmitters and clones
Input con gured as Bar 8k2 (Fig.G). Input for resistive edge 8K2.
ON
The command reverses movement for 1 sec.
OFF
Input con gured as Bar, safety edge (Fig.G).
OFF
The command reverses movement for 1sec..
ON
Enable safety check on the PHOT input. (Fig.G)
OFF
OFF
Safety check on PHOT input not enabled. (Fig.G)
ON
Enable safety check on the BAR input. (Fig.G)
OFF
OFF
Safety check on BAR input not enabled. (Fig.G)
In the event beam is broken, photocell operation is disabled during opening. During closing,
ON
movement is reversed immediately.
OFF
When beam is broken, photocells are active during both opening and clo-
sing. When beam is broken during closing, movement is reversed only once the
OFF
photocell is cleared.
ON
Safety edge with active reversal only when closing, when opening the movement stops
OFF
OFF
Safety edge with active reversal in both directions
ON
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
OFF
OFF
Logic not enabled
Sets the
automation type
ON
of operation:
ON = Apartment
building
OFF
OFF
OFF = Residential
Reaction to the START input (wired or radio):
Residential
CLOSED
Opens
WHILE CLOSING
Stops
OPEN
Closes
WHILE OPENING
STOPS + TCA
AFTER STOP
Opens
Reaction to the OPEN input (wired):
Residential
CLOSED
Opens
WHILE CLOSING
Opens
OPEN
No e ect
WHILE OPENING
Keeps it open
AFTER STOP
Opens
Reaction to the PEDESTRIAN input (radio):
Residential
CLOSED
Opens partially
WHILE CLOSING
Stops
OPEN
Closes
WHILE OPENING
STOPS + TCA
AFTER STOP
Opens partially
Apartment building
Opens
Opens
Closes
No e ect
Opens
Apartment building
Opens
Opens
No e ect
Keeps it open
Opens
Apartment building
Opens partially
Opens partially
Closes
No e ect
Opens partially