Terminal
70
71
72
73
74
75
Y
#
(*) If "D" type devices are installed (as de ned by EN12453), connect in unveri ed mode, foresee mandatory maintenance at least every six months.
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
TABLE "A" PARAMETERS
Any modi cation of parameters/logics must be con rmed by pressing S2 > 5s
TRIMMER
Parameter
Automatic
T1
closing time [s]
T2
Leaf strength [%]
T3
INSTALLATION MANUAL
De nition
Common
STOP, PHOT and BAR inputs common
The command stops movement. (N.C.)
STOP
If not used, leave jumper inserted.
PHOTOCELL input (N.C.).
PHOT (*)
Operation according to "PHOTOCELL/PHOTOCELL DURING CLOSING" logic. If not used, leave
jumper inserted.
FAULT 1
Test input for safety devices connected to PHOT.
Safety edge input (N.C.).
If not used, leave jumper inserted
BAR/8K2
dip
OFF
BAR /
BAR CL /
OFF
BAR TEST /
BAR CL TEST /
OFF
BAR 8K2 /
BAR CL 8K2
(*)
OFF
ON
ON
FAULT 2
Test input for safety devices connected to BAR / BAR CL
Antenna input.
ANTENNA
Use an antenna tuned to 433MHz. Use RG58 coax cable to connect the Antenna and Receiver.
Metal bodies close to the antenna can interfere with radio reception. If the transmitter's
SHIELD
range is limited, move the antenna to a more suitable position.
+
+
min.
max.
default
0
120
1
100
50%
Description
Safety edge
Safety edge
check
operation
dip
dip
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
+
Waiting time before automatic closing.
0
NOTE: Set to 0 if not used.
Force exerted by leaf/leaves.
ATTENTION: It directly a ects the impact force: check the set value
complies with the safety regulations in force(*). If necessary, install
anti-crushing safety devices.
Not used
NC input, no veri cation, reversal while
opening and closing (BAR)
NC input, no veri cation, reversal only when
closing, stop when opening (BAR CL)
NC input, with veri cation, reversal while
opening and closing (BAR TEST)
NC input, with veri cation, reversal only
when closing, stop when opening (BAR
CL TEST)
8K2 input, reversal when opening and
closing (BAR 8K2)
8K2 input, reversal only when closing, stop
when opening (BAR CL 8K2)