Displaying Transducer
Signals (cont.)
Option Bar Choice
=
Move the cursor to the left and display the amplitude and time in the
[F1]
<CURS
status line:
(i.e.
=
Move the cursor to the right and display the amplitude and time in the
[F2]
CURS>
status line:
(i.e.
=
Display the previous page
[F3]
<PAGE
=
Display the next page
[F4]
PAGE>
→]
=
Move the cursor to the start of the current page and post the starting date
[
+ [F1]
START
and time in the message line:
(i.e.
→]
=
Move the cursor to the end of the current page and post the ending date
[
+ [F2]
END
and time in the message line:
(i.e.
→]
=
Display the maximum Y value, which is set to 128 divisions in arbitrary
[
+ [F3]
YMAX
units, in the message line.
→]
=
Display the time increment value in the message line. This is based on the
[
+ [F4]
T INC
frequency of the transducers and would equal 0.125 μsec for a 1 MHz
transducer.
←]
=
Leave the graphical
[
+ [F1]
EXIT
data format. (The
Displaying Data
The typical display screen shown has the
to the left of the y-axis and there is a message line below the graph
that initially indicates the starting date and time of the graphed signal.
Notice that most of the locator bar has been replaced by a status line
in standard video that shows the signal amplitude and the time (in
microseconds) of the measurement at the current cursor location.
However, there is still an inverse video pointer at the far right of this
line to indicate that additional option bar choices are available. See
Table 2-7 below for a complete description of the nine functions
available on the option bar.
Table 2-7: Graphical Log Display Options
)
107 686.798mi
)
107 686.798mi
)
ST: 451.798usec
)
END: 744.298usec
display and return the display to the previous
SIGNL
key on the keypad will also perform this function.)
[EXIT]
In addition to the functions available on the option bar, some of the
numeric keys are used to specify which transducer signal is displayed
and to scale the resulting graph. Table 2-8 on page 2-12 lists these
functions.