Summary of Contents for Eaton Cutler-Hammer TD 17530A

  • Page 1 Cutler-Hammer TD 17530A Instructions for Installation, Operation and Maintenance of Cutler-Hammer IQ Analyzer Electrical Distribution System Monitor Effective 5/98...
  • Page 2 Power Distribution Components Division Five Parkway Center Pittsburgh, PA 15220 www.cutlerhammer.eaton.com All possible contingencies which may arise during installation, operation or maintenance, and all details and variations of this equipment do not purport to be covered by these instructions. If further information is desired by purchaser regarding his particular installation, operation or maintenance of particular equipment, contact a Cutler-Hammer representative.
  • Page 3 TD 17530A Page iv TABLE OF CONTENTS Page SECTION 1 INTRODUCTION/QUICK START Preliminary Comments and Safety Precautions....................1 1-1.1 Warranty and Liability Information ......................1 1-1.2 Safety Precautions ..........................1 1-1.3 Factory Correspondence ........................1 Product Overview ..............................1 1-2.1 Comprehensive Information .........................3 1-2.2 Harmonic Distortion Analysis .......................3 1-2.3 Extensive I/O and Communications Capabilities..................3 1-2.4...
  • Page 4 TD 17530A Page v Page 4-4.1 Before Power Application ........................26 4-4.2 Initial Power Application ........................26 Quick Start Metering............................27 SECTION 5 OPERATION General ................................43 Display Mode (“Meter Menu”)..........................43 5-2.1 Displayed Parameters ........................44 5-2.2 Displayed Sign Conventions ......................45 5-2.3 Display Manager ..........................47 5-2.3.1 Meter Menu Return Time ....................47 5-2.3.2...
  • Page 5 TD 17530A Page vi Page 5-7.2.5.4 Maximum ......................62 5-7.2.5.5 Maximum Demand..................62 5-7.2.5.6 Voltage Disturbance (Sag or Swell)..............62 5-7.2.5.7 Voltage Disturbance (Interruption or Excess DV/DT) - IQA-6200 Series Only..................63 5-7.2.5.8 Frequency Deviation..................63 5-7.2.5.9 Current Unbalance..................63 5-7.2.5.11 Discrete Input....................64 5-7.2.5.12 Manual Capture ....................64 5-7.2.5.13 Minimum/Maximum Update ................64 5-7.3 Harmonic Analysis..........................64...
  • Page 6 TD 17530A Page vii Page APPENDIX A STARTUP SETTINGS SHEETS General Setup Settings ...........................93 Analog Input Settings ............................94 Analog Output Settings ...........................95 Discrete Input Settings ............................96 Event Trigger Settings.............................98 Relay Output Settings ...........................106 Demand Settings............................111 Display Manager Settings ..........................112 GLOSSARY Terms and References..........................114 Effective 5/98...
  • Page 7 TD 17530A Page viii FIGURES Figure Title Page IQ Analyzer (Front View) ...........................2 IQ Analyzer (Rear View) with Optional IPONI ...................2 IQ Analyzer Operator Panel........................6 IQ Analyzer (Rear Views) ..........................7 Separate Source Power Module (Shown Mounted) ..................8 Self-Powered Three Phase Power Module (Unmounted)................8 Communication Module - IPONI - (Mounted) ....................9 Separate Source Power Module with Back Cover Removed ..............9 Typical Programming Screen ........................21...
  • Page 8 TD 17530A Page ix Figure Title Page 5-25 Typical Metered Event Voltage Screen ....................59 5-26 Representation of IQ Analyzer’s Handling of Setting Driven Alarms ............61 5-27 Typical Event Voltage Disturbance Screen .....................63 5-28 Typical Transient Waveform Display on IQA-6200 Series...............63 5-29 Typical Amps Selection Phase Screen....................64 5-30...
  • Page 9 TD 17530A Page 1 SECTION 1: INTRODUCTION/QUICK START HEADING IS SHOWN ABOVE IN REVERSE TYPE TO FAMILIARIZE PERSONNEL WITH THE STYLE OF PRESENTATION. THIS WILL HELP TO INSURE 1-1 PRELIMINARY COMMENTS AND SAFETY THAT PERSONNEL ARE ALERT TO WARNINGS, PRECAUTIONS WHICH MAY APPEAR THROUGHOUT THE DOCUMENT.
  • Page 10 TD 17530A Page 2 A unique operator interface, which includes a gas Series and IQA-6200 Series are similar in the features plasma display, easy to use “Meter Menu” screens and offered except that graphic and transient triggering detailed “Analysis” screens, permits an operator to abilities are also part of the IQA-6200 Series.
  • Page 11 TD 17530A Page 3 1-2.1 COMPREHENSIVE INFORMATION alarms and control relays. Terminals are captive clamp type and finger safe (Figure 2-2). With the The IQ Analyzer displays the most comprehensive list of communications option, IQ Analyzer can be remotely metered parameters in its class. Multiple parameters, monitored, controlled and programmed.
  • Page 12 TD 17530A Page 4 1-3 QUICK START In addition, an Appendix and Glossary are also provided as follows: This section is intended to provide an operator with enough basic information to put the IQ Analyzer into Appendix. Startup Setting Sheets. Provides a service quickly, without reviewing all of the instructions summary of settings and a place to logically record presented in this book.
  • Page 13 TD 17530A Page 5 Table 1.1 IQ Analyzer Ordering Information Device Description Catalog No. Style No. IQ Analyzer with self-powered three phase power module IQA6030 2D82302G01 IQ Analyzer with separate source power module IQA6010 2D82302G02 IQ Analyzer with dc power module IQA6020 2D82302G05 Self-powered, graphic displays and transient triggering...