We thank you for having chosen our company; our product is a great heating solution developed from the most advanced technology with top quality machining and modern design, aimed at making you enjoy the fantastic sensation that the heat of a flame gives, in complete safety. Warnings This instructions manual is an integral part of the product: make sure that it always accompanies the appliance, even if transferred to another owner...
Page 5
REcEiVED iNStRUctiONS ON SaFE USE OF thE aPPLiaNcE aND that thEY UNDERStaND thE iNhERENt DaNGERS. thE GENERatOR MUSt NOt BE USED BY PERSONS (iNcLUDiNG chiLDREN) With REDUcED PhYSicaL, SENSORY aND MENtaL caPacitiES OR WhO aRE UNSKiLLED PERSONS, UNLESS thEY aRE SUPERViSED aND tRaiNED REGaRDiNG USE OF thE aPPLiaNcE BY a PERSON RESPONSiBLE FOR thEiR SaFEtY.
(StRONG WiND, FREEziNG) SaFEtY SYStEMS MaY iNtERVENE that SWitch thE GENERatOR OFF. iF thiS OccURS, cONtact thE tEchNicaL aFtER-SaLES SERVicE aND aLWaYS DiSaBLE thE SaFEtY SYStEMS. iN thE EVENt thE FLUE catchES FiRE, USE SUitaBLE SYStEMS FOR SUFFOcatiNG thE FLaMES OR REQUESt hELP FROM thE FiRE BRiGaDE.
InstallatIOn general The flue gas exhaust and hydraulic connections must be carried out by qualified personnel who must issue installation conformity documentation compliant with national standards. the installer must provide the owner or person acting for him, according to the legislation in force, with the declaration of conformity, supplied with: 1) the use and maintenance manual of the appliance and of the system components (such as for example, the smoke ducts, chimney, etc.);...
Page 8
In the presence of type B gas appliances with intermittent operation not intended for heating, they must have their own aeration and/or ventilation opening. The air inlets must meet the following requirements: they must be protected with grids, metal mesh, etc., but without reducing the net useful section; ...
Hermetically sealed installation The generator is a fully sealed product with respect to the environment in which it is installed. This means that it is ideal for passive houses because it does not take air in from within the house. combustion air To ensure the stove remains hermetically sealed, the connection pipe for the combustion air must be directly connected to the exterior, using special pipes and sealed connectors.
Standards in force, national, regional and municipal, as well as these instructions. For Italy, installation must be carried out by professionally qualified staff (Ministerial Decree dated 22.01.08 n°37). Extraflame S.p.A. declines all responsibility for damage to objects and/or persons caused by the system. TYPE OF SYSTEM ...
DISTANCES OF SAFETY DEVICES ACCORDINg TO THE STANDARD The temperature safety sensors must be in place on the machine at a distance no greater than 30 cm from the flow connection. Whenever the generators lack a device, those missing can be installed on the generator flow pipe, within a distance no greater than 1 m from the machine. COMMISSIONINg CHECkS Before connecting the boiler: a) wash all system piping thoroughly in order to remove any residues which might compromise the correct functioning of certain system...
GUENDA IDRO DEtAIls Room air outlet Heat exchanger scrapers Door handle Heat exchanger scrapers Access to the ash drawer Pellet hopper Room air outlet Not used Fumes exhaust ON/OFF Fuse Power supply 230v Combustive air input HyDRAUlIc INstAllAtION 3 bar safety drain...
fEAtUREs Water content of the thermo-product heat exchanger (l) volume of expansion vessel integrated into thermo-product (l) 3 bar safety valve integrated into the thermo-product Minimum and maximum pressure switch integrated into the thermo-product Pump integrated into the thermo-product Pump max. head (m) ENViSiON aNY iNtEGRatiVE EXPaNSiON VESSEL ON thE BaSiS OF thE SYStEM WatER cONtENt.
stOvE pOsItIONING For correct product functioning, it is recommended to position it in a way that it is perfectly level, with the aid of a spirit level. NOtE fOR cORREct OpERAtION Pellet hopper lid The following indications must be respected for correct pellet stove operation: Both during the functioning and when the stove is not in use, all the machine doors (pellet hopper, fire door, ash drawer) must...
Pellets and feeding Pellets are made by subjecting wood shavings i.e. the rejects of pure wood (without paint) sawmill, carpenter products and products from other activities connected to working and transforming wood, to very high pressures. This type of fuel is fully ecological as no glues are used to hold it together. In fact, the compactness of the pellets is guaranteed over time by a natural substance that is found in wood: wood coal.
Remote contRol The remote control can be used to adjust the main stove functions. Transmitter Select air mode* Display Lock keyboard On/off stove (hold for 3 seconds) Degrees Celsius / Fahrenheit Set power Press the button once to enable or disable the chrono Set switch-off delay: The button allows to set the switch- off delay.
Remote contRol Icons Air mode selected: * Enable chrono Flashing COMFORT Light on = activated On AUTO Light off = deactivated Indicates the transmission of the radio signal Set switch-off delay * On = during all radio communication Off = radio communication absent Battery low Keys locked Set power level.
Control Board ViewiNg OF VariOUs TO aCCess ON/OFF TexT messages THe meNU BUTTON OPeraTiNg POwer TemPeraTUre ICon key indicates the presence of an alarm. indicates the status of the weekly programming Off: indicates that there are no alarms Off: deactivated. On: indicates the presence of an alarm On: activated.
General menu go back - exit scroll parameters: next (3); previous (2) Change settings data: increase (4); decrease (5) Confirm - access menu VENtiLatiON ENaBLiNG SPEED EaSY SEtUP SEt thERMOStat chRONO ENaBLiNG PRG1 PRG2 SEttiNGS DatE-tiME PRG3 LaNGUaGE PRG4 DiSPLaY StaND BY FiRSt LOaD OUtLEt aiR...
FIrst IGnItIon settInGs Once the power cord at the back of the stove has been connected, move the switch, also located on the back, to (i). the switch at the back of the stove powers the stove board. the stove remains off and a first screen appears on the panel reading OFF . date-tIme This menu allows the date and time to be set.
oPeratIon and loGIC IGnItIon Once the points listed previously have been checked, press key 1 for three seconds to ignite the stove. 15 minutes are available for the ignition phase. after ignition and having reached the control temperature, the stove interrupts the ignition phase and switches to sTarTiNg. PreParatIon During the preparation phase, the stove stabilises combustion, increasing it progressively, then switches to wOrK.
addItIonal tHermostat n.B. : InstallatIon must Be PerFormed By an autHorIsed teCHnICIan it is possible to control the temperature of a room adjacent to the room where the stove is positioned; simply connect a thermostat following the procedure described in the following section (it is advisable to place the optional mechanical thermostat at a height off the ground equal to 1.50 m).
ventIlatIon This menu allows to enable or disable the operation of the tangential motor and to adjust the speed (-2, -1, 0, +1, +2) of the front fan. The SEt thERMOStat allows to set the room temperature to be reached (front ventilation must be active). Once the temperature set in SEt tEMPERatURE has been reached, the ventilation will turn OFF and then it will turn back on when required.
CHrono This function allows stove ignition and switch-off to be automatically programmed. The factory setting for CHrONO is off. The chrono allows the programming of 4 time slots per day, which can be used every day of the week. For each time slot, it is possible to set ignition and switch-off times, specific days of application, desired temperature and set power. current day and time settings are essential for the correct operation of the chrono.
Page 25
EXaMPLE OF chRONO OVERLaPPiNG tiMES/SLOtS Time sLOT 02:00 08:00 16:30 23:00 seT POwer 02:00 08:00 16:30 23:00 seT H2O 72° 68° 02:00 08:00 16:30 23:00 start 02:00 Time slot 1 Power 3 - seT H2O 72°C stop 23:00 start 08:00 Time slot 2 Power 1 - seT H2O 68°C stop 16:30...
settInGs DatE-tiME LaNGUaGE See chapter: firSt ignition SettingS SEt DEGREES dIsPlay This menu allows you to adjust the brightness of the display. The values range from OFF, 1 to 20. if set to OFF, the display backlighting is set to maximum brightness and turns off after a 60 second delay.
OUtLEt aiR This function allows any air in the stove to be discharged. By activating the pump function, it will be powered alternatively with 30 second work phases and 30" stop for 15 minutes. with the stove cold and "OFF", activate the OUtLEt aiR function and press 6 to confirm. To interrupt, press and hold key 1 for 3 seconds.
addItIonal FunCtIons keys loCked This function allows you to lock the display keys (similar to mobile phones). with the function active, each time a key is pressed, the message “KEYS LOcKED" will appear To lock the keypad, press keys 1 and 5 simultaneously until the following message appears: "KEYS LOcKED" To unlock the keypad, press keys 1 and 5 simultaneously until the following message appears: "KEYS UNLOcKED"...
FiND OUt WhERE YOUR NEaRESt SERVicE cENtRE iS, cONtact YOUR DEaLER OR ViSit thE WEBSitE: WWW.LaNORDica-EXtRaFLaME.cOM CLEANING AND MAINTENANCE ALWAYS FOLLOW THE INSTRUCTIONS IN COMPLETE SAFETY! For all operations, except for routine cleaning, make sure that the power cord plug is disconnected as the generator may have been programmed to turn on.
Page 30
COMbUSTION CHAMbER By means of a mechanical system, the burn pot is cleaned automatically at preset intervals. It is however advisable to remove any residues by using a vacuum cleaner. Suck the ash deposited between the partition and the fire holder (1). ...
A CLEAN bURN POT GUARANTEES CORRECT OPERATION! bY kEEPING THE bURN POT AND ITS HOLES CONSTANTLY CLEAN AND FREE OF COMbUSTION RESIDUE, EXCELLENT COMbUSTION IS GUARANTEED OVER TIME, THUS PREVENTING ANY GENERATOR MALFUNCTIONS THAT MAY REQUIRE TECHNICAL ASSISTANCE. THE “EASY SETUP” FUNCTION IN THE USER MENU CAN bE USED TO ADAPT COMbUSTION ACCORDING TO THE NEEDS DESCRIbED.
Page 32
FiND OUt WhERE YOUR NEaRESt SERVicE cENtRE iS, cONtact YOUR DEaLER OR ViSit thE WEBSitE: WWW.LaNORDica-EXtRaFLaME.cOM THE iMAgES ARE foR illUSTRATiVE PURPoSES. Fumes motor (disassembly and cleaning and fumes pipe and "T"), new silicone in the provided points Gaskets, pellet hopper, inspections, ash drawer and door (replace and apply silicone where indicated) Combustion chamber and heat exchanger (full cleaning) including ignition plug pipe Hopper (complete emptying and cleaning).
Displays Display Reason Generator off sTaRT The start-up phase is in progress pelleT loaDinG Continuous pellet feeding is in progress during the ignition phase iGniTion The ignition phase is in progress pRepaRaTion The PREPARATION phase is in progress WoRK The normal work phase is in progress MoDUlaTion The generator is working at minimum **BURn poT CleaninG...
Page 34
Turn the stove off using key 1 and repeat the procedure described in the iGniTion No power during the ignition phase. "IGNITION" chapter. BlaCK oUT Other reset operations should be performed by an authorised technician. The pellet hopper is empty. Check for the presence of pellets in the hopper.
Disposal iNFORMatiON FOR MaNaGEMENt OF ELEctRic aND ELEctRONic aPPLiaNcE WaStE cONtaiNiNG BattERiES OR accUMULatORS This symbol, which is used on the product, batteries, accumulators or on the packaging or documents, means that at the end of its useful life, this product, the batteries and the accumulators included must not be collected, recycled or disposed of together with domestic waste. Improper management of electric or electronic waste or batteries or accumulators can lead to the leakage of hazardous substances contained in the product.
Page 36
EXtRaFLaME S.p.a. Via Dell’Artigianato, 12 36030 - MONTECCHIO PRECALCINO (VI) - ITALY +39.0445.865911 - +39.0445.865912 - info@extraflame.it - www.lanordica-extraflame.com MADE ITALY design & production TO FIND THE SERVICE CENTRE NEAREST TO YOU CONTACT YOUR DEALER OR CONSULT THE SITE WWW.LANORDICA-EXTRAFLAME.COM...