FISCHER DA01 Instruction Manual

FISCHER DA01 Instruction Manual

Differential pressure gauge
Hide thumbs Also See for DA01:

Advertisement

Quick Links

Instruction Manual
DA01 Differential Pressure Gauge

Table of Contents

1.
Safety Instructions
2.
3.
4.
5.
6.
7.
8.
9.
12. Dimensions
13. Ordering Code
14. Declaration of Conformity
1.
Safety Instructions
1.1.
personnel responsible for the equipment must
read this thoroughly before attempting to install or
operate this equipment. A copy of this manual
must always be kept accessible at the place of
work for reference by concerned personnel.
Chapter 1 (sections 1.2 through 1.7) contains ge-
neral as well as specific safety instructions. Chap-
ters 2 through 10, covering topics ranging from
intended purpose of the equipment to its final dis-
posal, also include important points relating to
safety. Overlooking or ignoring any of these safety
points can endanger humans and animals, and
possibly cause damage to other equipment.
This manual contains detailed
information about the product
and instructions for its installati-
on, operation and maintenance.
Operators and other technical
1.2.
Personnel Qualification
Personnel responsible for installation, operation,
maintenance and inspection of this product must
have the qualifications, training and experience
necessary to carry out such work on this type of
equipment.
1.3.
Risks of Disregarding Safety Instruc-
tions
Disregarding safety instructions, use of this pro-
duct for purposes for which it is not intended, and/
or operation of this product outside the limits spe-
cified for any of its technical parameters, can result
in harm to persons, the environment, or the plant
on which it is installed. Fischer Mess- und Regel-
technik GmbH will not be responsible for conse-
quences in such circumstances.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DA01 and is the answer not in the manual?

Questions and answers

Summary of Contents for FISCHER DA01

  • Page 1: Table Of Contents

    Chapter 1 (sections 1.2 through 1.7) contains ge- on which it is installed. Fischer Mess- und Regel- neral as well as specific safety instructions. Chap- technik GmbH will not be responsible for conse- ters 2 through 10, covering topics ranging from quences in such circumstances.
  • Page 2: Intended Applications

    This limits the pres- sure differential across the lower pressure diaphragm, The DA01 is used for indication and switching differential and equalizes the pressure across the higher pressure pressure of gaseous and liquid media. The product must diaphragm.
  • Page 3: Installation

    Installation serted into the pressure lines. • Pressure lines must be kept as short as possible and The instrument is intended for plate mounting. There are 2 boreholes (M8) on the rear to fix the instrument on the must not have short bends to avoid measurement er- mounting plate.
  • Page 4: Maintenance

    Press axle inwards until the actuating arm interlocks with the actuating pins. Any defective devices or devices with missing parts should be returned to Fischer Mess- und Regeltechnik • Turn adjustment key until setpoint value pointer rea- GmbH. For quick service contact our service department.
  • Page 5: Specifications

    11. Specifications General Range See Ordering Code Max. pressure load Overpressure safe up to max. operating pressure Max. static operating pressure PN 250; PN 400 (see Ordering Code) Indication Circular dial type 100 or 160 diameter Scale design acc. to DIN, 270° Accuracy ±...
  • Page 6 12. Dimensions (all units in mm unless otherwise stated) Rinsing connection G1/8 female Differential Pressure Gauge DA01 Model: Range (60 ... 400) mbar Rinsing connection G1/8 female Differential Pressure Gauge DA01 Model: Range (0.6 ... 25) bar...
  • Page 7 13. Ordering Code Differential Pressure Gauge DA01 Range 0 . . . 60 mbar................> 5 0 . . . 100 mbar................> 5 0 . . . 160 mbar................> 6 0 . . . 250 mbar................> 8 0 . . . 400 mbar................> 8 0 .
  • Page 8 Technische Änderungen vorbehalten • Subject to change without notice • Changements techniques sous réserve Fischer Mess- und Regeltechnik GmbH • Bielefelder Str. 37a • D-32107 Bad Salzuflen • Tel. +49 5222 9740 • Fax +49 5222 7170 eMail: info@fischermesstechnik.de • www.fischermesstechnik.de...

Table of Contents