Operational characteristics

This section describes the operational characteristics including:
● PSU input range that can be configured in several ways
● Power consumption
● Heat dissipation
8.1

PSU input range

8.1.1

PSU input configuration 0,1

Parameter
Main power supply voltage
8.1.2

PSU input configuration 2

Parameter
Main power supply voltage
8.1.3

PSU input configuration 3

Parameter
Main power supply voltage
8.2

Power consumption

Providing theoretical maximum power consumption value would be
useless for the majority of system designers building their application
upon AXEL ULite module because, in most cases, this would lead to an
over-sized power supply unit. Several configurations have been tested in
order to provide figures that are measured on real-world use cases
instead. Please note that AXEL ULite platform is so flexible that it is
virtually impossible to test for all possible configurations and applications
on the market. The use cases here presented should cover most of real-
world scenarios. However actual customer application might require more
power than values reported here. Generally speaking, application specific
requirements have to be taken into consideration in order to size power
v.1.0.2
Min
Typ
3.135
3.3
Min
Typ
3.3
3.7
Min
Typ
3.25
3.3
August, 2019
Max
Unit
3.465V
Max
Unit
4.5V
Max
Unit
3.465V