Toshiba Q7 Installation And Operation Manual page 46

Adjustable speed drive
Table of Contents

Advertisement

OUT2 On Delay
OUT2 On Delay
OUT4 Terminal
OUT4 Off Delay
OUT4 On Delay
OUT5 Terminal
OUT5 Off Delay
OUT5 On Delay
OUT6 Terminal
OUT6 Off Delay
OUT6 On Delay
OUT7 Terminal
OUT7 Off Delay
OUT7 On Delay
Output Current
Output Phase Loss
Output Power
Output Terminals
Output Voltage
Overcurrent Stall Level
Overload Reduction Frequency
Overspeed Frequency
Overtorque Detect Time
Overtorque Level Negative
40
This setting delays the On response-time of the OUT2 terminal to an input
command.
Multifunctional programmable discrete output (Multicom expansion card
required).
This setting delays the Off response-time of the OUT4 terminal to an input
change.
This setting delays the On response-time of the OUT4 terminal to an input
command.
Multifunctional programmable discrete output (Multicom expansion card
required).
This setting delays the Off response-time of the OUT5 terminal to an input
change.
This setting delays the On response-time of the OUT5 terminal to an input
command.
Multifunctional programmable discrete output (Multicom expansion card
required).
This setting delays the Off response-time of the OUT6 terminal to an input
change.
This setting delays the On response-time of the OUT6 terminal to an input
command.
Multifunctional programmable discrete output (Multicom expansion card
required).
This setting delays the Off response-time of the OUT7 terminal to an input
change.
This setting delays the On response-time of the OUT7 terminal to an input
command.
The current that is applied to the motor displayed as a percentage of the
maximum output of the ASD.
Enables/Disables the monitoring of each phase of the 3-phase output signal (U,
V, and W) of the ASD. If either line is missing, inactive, or not of the specified
level, the ASD incurs a trip.
Displays the output power in kW.
Displays the active output terminals of the ASD.
The voltage that is applied to the motor displayed as a percentage of the
maximum output of the ASD.
This setting specifies the output current level at which the output frequency is
reduced in an attempt to prevent a trip.
This setting is used to reduce the start frequency during very low-speed motor
operation. During very low-speed operation the cooling efficiency of the motor
decreases. Lowering the start frequency aides in minimizing the generated heat.
A user-set frequency that, once exceeded, will cause an Overspeed Alert.
This setting determines the amount of time that the overtorque condition may
exceed the tripping threshold level before a trip occurs.
This setting determines the torque threshold level that is used as a setpoint for
overtorque tripping during regeneration.
Overtorque Level Negative
Q7 ASD Installation and Operation Manual