GREEN
WHITE
Items to check:
Check blower for obstructions:
*Clean fan blades & check fan bearing.
Check blower connections
*Color of wires, Connector pins, test for broken wires
Check over heat snap disc (#230-1290)
*This is located on the pellet drop chute. Is it tripped?
Replace exhaust blower:
*If all previous checks are good, replace the blower.
Replace the control board (SRV7000-456):
*If replacing the blower did not work, replace the board.
9-30-2010

EXHAUST BLOWER TROUBLE-SHOOTING

EXHAUST BLOWER
#7034-033
RED
WHITE
BLACK
BLUE
GREEN
PAGE 11
Wall Control Error Code
7020-057D