ART 4 LITE/G2+ MONITOR
Continued from previous page.
SPECIAL CODES
( )
Configuration of the remote activation button
*
Delay
( )
Configuration of the remote activation button
*
Delay
.
.
( )
LED lights for night viewing (Door panel ) during a call or communication process. (Configure only on the
*
master monitor).
Automatic
2450
.
( )
Activation times of the outputs (Door panel ). (Configure only on the master monitor).
*
Relay 1
Relay 2
.
( )
Configuration of the remote activation button
*
Delay
.
( )
Configuration of the remote activation button
*
Delay
.
( )
LED lights for night viewing (Door panel ) during a call or communication process. (Configure only on the
*
master monitor).
Automatic
3450
.
( )
Activation times of the outputs (Door panel ). (Configure only on the master monitor).
*
Relay 1
Relay 2
.
( )
Configuration of the remote activation button
*
Delay
.
( )
Configuration of the remote activation button
*
Delay
.
To define the light up duration time from 1 to 99 seconds (SAR-G2+ Relay). (
.
To define the light up delay time from 0 to 99 seconds (SAR-G2+ Relay). (
Configuration as a guard monitor. (Configure only on the master monitor).
From 1400 (0,5s) to 1419 (10s)
From 1500 (0,5s) to 1519 (10s)
Always ON
2451
From 2200 (0,5s) to 2219 (10s)
From 2300 (0,5s) to 2319 (10s)
From 2400 (0,5s) to 2419 (10s)
From 2500 (0,5s) to 2519 (10s)
Always ON
3451
From 3200 (0,5s) to 3219 (10s)
From 3300 (0,5s) to 3319 (10s)
From 3400 (0,5s) to 3419 (10s)
From 3500 (0,5s) to 3519 (10s)
From 1801 (1s) to 1899 (99s)
From 1900 (0s) to 1999 (99s)
End guard monitor
5000
Relay1
(Door panel ). (Configure only on the master monitor).
2
Relay2
(Door panel ). (Configure only on the master monitor).
2
3
Always
OFF
2452
3
Relay1
(Door panel ). (Configure only on the master monitor).
3
Relay2
(Door panel ). (Configure only on the master monitor).
3
4
Always
OFF
3452
4
Relay1
(Door panel ). (Configure only on the master monitor).
4
Relay2
(Door panel ). (Configure only on the master monitor).
4
Guard monitor
5001
5000 (End guard monitor)
Factory setting
1403 (2s)
Factory setting
1503 (2s)
Factory setting
2450 (automatic)
.
Factory setting
2205 (3s)
2305 (3s)
Factory setting
2403 (2s)
Factory setting
2503 (2s)
Factory setting
3450 (automatic)
.
Factory setting
3205 (3s)
3305 (3s)
Factory setting
3403 (2s)
Factory setting
3503 (2s)
Configure only on the master monitor
Factory setting
1803 (3s)
.
Configure only on the master monitor
Factory setting
1900 (0s)
Factory setting
25
).
).