L - Belt Removal - Chicago Pneumatic QRS 20 Instruction Manual

Cp compressor
Table of Contents

Advertisement

20
25
30
Table 1

L - Belt removal

- Take off the rear panel (1)
- Remove the protection plate (2)
- Using an Allen, unscrew the four tightening screws (3) of the
plunger from the support
- Using an hexagonal wrench by 19, unscrew the lockup nut as
shown in the Fig. 18
- Remove the inlet nozzle Fig. 19
- Replace the worn out belts Fig. 20
- Tight the belts using a hexagonal wrench by 19, according the
Table 1. If no tension measuring device is available, use the
method shown on Fig 17.
- Fix the nut and the locknut using an hexagonal wrench by 19
- Lockup the tightening nut using an Allen
- Place the protection plate
- Place the rear panel back
When the compressed air cools, part of the moisture sucked in by the compressor condenses. In order to protect the dryer against
the risk of an ice plug forming, it is essential to check regularly that the condensate drains are operating properly :
On the compressed air storage reservoir and on the filters :
• With a manual drain, drain regularly according to the moisture content of the ambient air.
• With an automatic drain, set the draining cycle accordingly and check that the drain is in good working condition.
This recommendation is also fundamental in a circuit comprising an absorption dryer (risk of saturation of the alumina).
01/2008
Page 24
100
193.4
125
193
150
186.9
175
177.3
100
242.6
125
231.3
150
228.1
175
225.9
100
304.6
125
312
150
300
175
245.9
CAUTION
Fig. 18
Fig. 19
Fig. 20
Chicago Pneumatic Compressors
62 305 454 65