1. TECHNICAL DATA
Definition: according to EN 13240
Constructive system
Nominal thermal power in kW
Efficiency in %
Smoke outlet diameter in mm
Chimney height ≥ (m) - dimensions min (cm) (#)
Chimney draught in (mm H
Hourly wood consumption in kg / h (wood with 20% humidity)
CO measured at 13% oxygen in %
Exhaust gas emission in g/s
Exhaust gas temperature in °C
Outer air inlet in mm (Ø)
Hearth opening size in mm (W x H)
Hearth size in mm (W x H x D)
Oven size in mm (W x H x D)
Type of grill
Height in mm
Width in mm
Depth (with handles) in mm
Weight in Kg
Fire prevention safety distances
The heating volume of the stoves according to EN 13240 for those buildings in which the thermal insulation does not correspond to the
instructions on heat protection is:
With a suitable thermal insulation, complying with the instructions on heat protection, the heating volume is greater. In case of temporary
heating, with interruptions of more than 8 hours, the heating volume is reduced by about 25%.
2. GENERAL PRECAUTIONS
La NORDICA S.p.A. responsibility is limited to the supply of the appliance.
The installation must be carried out scrupulously according to the instructions provided in this manual and the rules of the profession.
Installation must only be carried out by a qualified technician who works on behalf of companies suitable to assume the entire responsibility
of the system as a whole.
La NORDICA S.p.A. declines any responsibility for the product that has been modified without written authorisation as well as
for the use of non-original spare parts.
This appliance is not suitable for the use of inexperienced people (included children) or with physical, sensorial and mental reduced
capacities. They have to be controlled and educated in the use of the appliance from a responsible person for their security. The children
have to be controlled to be sure that they would not play with the appliance. (EN 60335-2-102/7.12).
It is OBLIGATORY to respect the National and European rules, local regulations concerning building matter and also fireproof
rules. NO MODIFICATIONS CAN BE CARRIED OUT TO THE APPLIANCE. NORDICA S.p.A. cannot be held responsible for lack of
respect for such precautions.
"7097030 - IT - EN - DE - FR"
O)
2
((#) 200 mm diameter can be used with flue of no less than 6 m
(30 Kcal/h x m
) - favourable type of building:
3
(40 Kcal/h x m
) - less favourable type of building:
3
(50 Kcal/h x m
) - unfavourable type of building:
3
1
9,4
78,6
160
4 - 250x250 Ø250
1,4
2,8
0,10
9,5
268
150
465 x 320
425 x 365 x 285
-
FLAT
1338
716
532
249
Chapter 4
268 m³
202 m³
160 m³
15