  • Page 1 IDS 900 ORIGINAL INSTRUCTIONS OIL HEATER...
  • Page 2: Table Of Contents

    • Only put up the device in an upright, stable position on firm moderate injury. ground. • Let the device dry out after a wet clean. Do not operate it when wet. oil heater IDS 900...
  • Page 3 • Make sure that the suction side is kept free of dirt and varnishes or other easily inflammable vapours or in rooms loose objects. where these substances are stored. • Do not place the device on combustible ground. • Do not use the device out of doors. oil heater IDS 900...
  • Page 4 The nameplate is provided on the device in German and English: Type: IDS 900 Article no.: 1430000160 Heating capacity: 236 kW Air volume flow: 17000 m³/h Mains connection: 1/N/PE ~ 230 V/50 Hz Fuel consumption: 21.69 l/h Tank content: -I Fuel: diesel (10 % biodiesel maximum) or kerosene oil heater IDS 900...
  • Page 5 Risk of death due to suspended loads! Make sure that nobody is situated in the immediate proximity. Warning Risk of suffocation! Do not leave the packaging lying around. Children may use it as a dangerous toy. oil heater IDS 900...
  • Page 6: Information About The Device

    The combustion products are discharged into the open air through a flue pipe. The sucked-in air is heated and fed back to the environment via the air outlet. oil heater IDS 900...
  • Page 7: Transport And Storage

    Stop bolt • with a cover to protect it from invasive dust, if necessary Flue pipe connection Control box Cooling fan Protective bar Wheel Thermostat housing Foot Burner housing Transport handle Tank connection with cover oil heater IDS 900...
  • Page 8: Assembly And Start-Up

    ð Make sure that the values of the power supply network correspond to the specifications on the identification plate. 2. Then connect the power cable to a properly secured socket. On construction sites, there must be an RCD upstream of the socket according to VDE 0100/0105. oil heater IDS 900...
  • Page 9 • directly using the fuel oil pump of the burner Observe the dimensions and lengths specified in the burner's operating manual. • indirectly using an auxiliary pump for the fuel oil Contact the customer service for a proper dimensioning of the system. oil heater IDS 900...
  • Page 10 • The inlet and outlet openings must not be covered. • There must be no walls or large objects near the device. • There must be a sufficient number of fire extinguishers available. oil heater IDS 900...
  • Page 11 The initial start-up must be carried out by a qualified completeness. If the scope of delivery is incomplete, electrician who verifies whether the combustion please contact the Trotec customer service or the parameters are correct. specialist dealer where you purchased the device.
  • Page 12: Operation

    6. Make sure that the hose is firmly attached to avoid leakage. 7. The device is now connected to the oil supply. Note If the tank is empty, the burner flame extinguishes and the device switches off automatically. oil heater IDS 900...
  • Page 13 Is illuminated when the fan is switched on. Temperature Records the outlet temperature and controller with the operating hours. Control of the trigger temperature of the burner thermostat and fan thermostat. Display Indicates the measured temperature in °C. oil heater IDS 900...
  • Page 14 ð The green power operating control lamp (26) lights up. ð The fan (5) is switched on. • Press the manual reset of the safety thermostat (21) to restart the air heater. oil heater IDS 900...
  • Page 15 3. Enter the code "-481" by pressing the ▼ button (29) several times until the desired indication appears. Press the P button (30) to confirm and to move to the next indication. 4. Then press the U button (27). ð The air outlet temperature is displayed again. oil heater IDS 900...
  • Page 16: Available Accessories

    ü Allow the device to cool down completely. 1. Remove the feed and return hose from the tank connection of the external tank. 2. Remove the feed and return hose from the tank connection (12) of the device. oil heater IDS 900...
  • Page 17: Errors And Faults

    • Inspections and measures do not produce any results: Tasks which require the device to be opened must only be carried out by authorised specialist Contact the Trotec customer service. companies or by Trotec. Warning Risk of injury due to improper repair! Never try to make any modifications or repairs on the device.
  • Page 18 Irregular operation of the burner Should this situation reoccur after ignite and the reset indicator and the pressing the burner reset button (24) control system is illuminated and after restarting the device, please contact the technical customer service. oil heater IDS 900...
  • Page 19 The fan makes noises or vibrates Foreign object on air inlet Remove foreign objects and dirt Insufficient air circulation Remove foreign objects and dirt Insufficient heating Insufficient heat output of the burner Please contact the technical customer service. oil heater IDS 900...
  • Page 20: Maintenance

    Check the thermostats Check the electrical connections Clean the motor and fan Checking and testing the burner Clean combustion chamber Check fuel oil supply line Check the air heater Clean heat exchanger Clean the interior Test run oil heater IDS 900...
  • Page 21 10. Date: ........11. Date: ........12. Date: ........Signature: ........ Signature: ......... Signature: ......... Signature: ......... 13. Date: ......... 14. Date: ........15. Date: ........16. Date: ........Signature: ........ Signature: ......... Signature: ......... Signature: ......... oil heater IDS 900...
  • Page 22 • that the device is in a stable position • the device is not positioned in areas with a high risk of fires or in potentially explosive atmospheres • a safety distance from flammable substances is maintained oil heater IDS 900...
  • Page 23: Technical Annex

    2 m 4. If necessary, have intact connections, wires or plug front 2 m connectors replaced by the Trotec customer service. Weight (with empty tank) 351 kg Check the thermostats Burner (see operating manual of the burner) Proceed as follows to check the thermostats: Fuel oil pressure of the burner 13 bar...
  • Page 24 TA Room thermostat RV Switch heating-stop- ventilation F Air controller ST Indicator light PB Burner SL Overheating protection indicator light, L1, L2 FB Fuse for burner 6A SB Fan "OFF" L1 Overheating protection indicator light thermostat, L1 oil heater IDS 900...
  • Page 25 Overview of spare parts IDS 900 Note! The position numbers of the spare parts differ from those describing the positions of the components mentioned in these instructions. oil heater IDS 900...
  • Page 26 Panel Ground terminal board Aluminium washer Panel Fuse holder Diesel filter Support bracket Fuse Filter cartridge Panel Support plate Filter seal kit Support Cable fastener Filter container Wheels axle support bracket Cable fastener nut Iron fitting oil heater IDS 900...
  • Page 27: Disposal

    The icon with the crossed-out waste bin on waste electrical or electronic equipment stipulates that this equipment We – Trotec GmbH – declare in sole responsibility that the must not be disposed of with the household waste at the end of product designated below was developed, constructed and its life.