Notice This signal word indicates important information (e.g. material damage), but does not indicate hazards. Info Information marked with this symbol helps you to carry out your tasks quickly and safely. Operating manual – oil heater IDX 30 D...
• Ensure that the side of the device where the air inlet is found is kept free of dirt and loose objects. • Ensure that the air inlet and outlet are not obstructed. • Only transport the device in an upright position. Operating manual – oil heater IDX 30 D...
Page 4
Take sufficient precautions when handling fuels such as fuel oil, kerosene or diesel. Do not spill any diesel, kerosene or fuel oil! Do not inhale the vapours nor swallow any fuel! Avoid skin contact! Operating manual – oil heater IDX 30 D...
Designation upper part of the housing air inlet with protective grid transport handle fan and motor pressure gauge tank frame control panel fuel tank cap wheel tank filling level indication air outlet Operating manual – oil heater IDX 30 D...
Page 7
There must be no walls or large objects near the device. • The inlet and outlet openings must not be covered. • There must be a sufficient number of fire extinguishers available. Operating manual – oil heater IDX 30 D...
The device may only be used by accordingly instructed persons. completeness. If an accessory part is missing, please Operating elements contact the Trotec customer service or the specialist dealer where you purchased the device. • Check the device and its connection parts for potential damage.
Noise emission during ignition or cooling. The metal parts of the device expand when heated and This is not a fault. generate noise Sparks and/or flame may be issued from Air might have accumulated in the lines. This is not a fault. the device during ignition. Operating manual – oil heater IDX 30 D...
Page 10
Refill new fuel, see chapter Filling the tank. Your device still does not operate correctly after these checks? Please contact the customer service. If necessary, bring the device to an authorized specialist electrical company or to Trotec for repair. Operating manual – oil heater IDX 30 D...
ü Before attempting to fill the tank, wait until the device has cooled down completely. ü Only use fuel suitable for the device (see technical data). 1. Position the device on firm, level and incombustible ground. 2. Unscrew the fuel tank cap (9). Operating manual – oil heater IDX 30 D...
Page 12
500 operating hours. The fan ought to be checked for dirt at least once per heating season. This activity can be carried out along with the inspection of the air filters. Operating manual – oil heater IDX 30 D...
Page 13
Ensure that no moisture enters the housing. Protect electrical components from moisture. Do not use any aggressive cleaning agents such as cleaning sprays, solvents, alcohol-based or abrasive cleaners to dampen the cloth. Operating manual – oil heater IDX 30 D...
Page 14
Replace the prefilter (31) if needed. If required, clean the foam filter (32) using a slightly damp, soft, lint-free cloth. If the foam filter is heavily contaminated, clean it with warm water mixed with a neutral cleaning agent. Operating manual – oil heater IDX 30 D...
Page 15
4. Insert both filters into the filter housing (33). Ensure the proper seating of the seal (30). Assembling the filter housing 1. Attach the filter housing with filters and sealing. 3. Fasten the pressure gauge in place. Operating manual – oil heater IDX 30 D...
Page 16
Assembling the upper part of the housing 1. Place the upper part of the housing on the device. 4. Tighten the 4 screws at the protective grid. 2. Tighten the 8 screws at the upper part of the housing. Operating manual – oil heater IDX 30 D...
Dimensions (length x width x height) 388 x 942 x 460 (mm) Minimum distance to walls or other objects Fuels The following fuels are approved for the device: • EL fuel oil • Kerosene • Diesel Operating manual – oil heater IDX 30 D...
Page 19
Spare parts drawing and list Info The position numbers of the spare parts differ from those describing the positions of other parts mentioned in this operating manual. Operating manual – oil heater IDX 30 D...
You are responsible for deleting any personal data stored on the waste equipment to be disposed of. Fuel oil The fuel oil must be drained from the device and collected. Fuels are to be disposed of according to the national regulations. Operating manual – oil heater IDX 30 D...
Page 22
Trotec GmbH & Co. KG Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.com...