• Do not use the device in potentially explosive rooms or areas and do not install it there. oil heater IDS 45 / IDS 80...
Page 3
Defective power cables pose a serious health risk! Safety chapter. • When positioning the device, observe the minimum distances from walls and other objects as well as the storage and operating conditions specified in the Technical annex. oil heater IDS 45 / IDS 80...
Page 4
Warning of hot surface Improper handling entails a risk of burning. Only use the device as intended! Warning Improper handling entails a risk of burning and electric shock. Only use the device as intended! oil heater IDS 45 / IDS 80...
Support The sucked-in air is heated and fed back to the environment via Fuel tank cap the air outlet. Cable holder Wheel Tank Control panel Air outlet for hot air oil heater IDS 45 / IDS 80...
• dry and protected from frost and heat • in an upright position where it is protected from dust and direct sunlight • with a cover to protect it from invasive dust, if necessary oil heater IDS 45 / IDS 80...
Page 7
1. Place the transport handle (5) and support (6) on the rear tank side. 2. Make sure that the holes in the transport handle are aligned with the holes in the support and the holes on the tank. oil heater IDS 45 / IDS 80...
Page 8
Below are some examples of good and bad exhaust gas discharge: max. 10 m oil heater IDS 45 / IDS 80...
Page 9
≥ Ø 150 mm chimney – inside min. 20 x 20 cm Chimney duct min. 1 m wall duct with elbow The following schematic representation should be considered min. 5° when planning a chimney duct: draught booster H-shaped oil heater IDS 45 / IDS 80...
Page 10
If an accessory part is missing, please are people or animals in the same room with the device! contact the Trotec customer service or the specialist dealer • The minimum distance between walls or other objects and where you purchased the device.
Make Power supply cable sure that the fuel tank cap is firmly attached to avoid Thermostat socket leakage. Selector switch (continuous operation/thermostat operation) Operating light Reset button with indicator light oil heater IDS 45 / IDS 80...
Page 12
Illuminated in Internal error of an electronic controller 3. Wait until the automatic after-cooling is completed. orange 4. Secure the device against inadvertent switch-on by pulling the mains plug. oil heater IDS 45 / IDS 80...
Tasks which require the device to be opened must number number only be carried out by authorised specialist companies or by Trotec. Adapter 350 mm for IDS 45 6.100.006.164 - Adapter 400 mm for IDS 80 - 6.100.006.165 Warning 2-way distributor for IDS 45 6.100.006.166 -...
Page 14
• Check the mains voltage. • Check the fuel for contaminations and replace it if required. • Check the tank for contaminations and drain it if required (see chapter Maintenance). Refill with clean fuel. oil heater IDS 45 / IDS 80...
Page 15
Magnet valve faulty Charge the customer service with the following tasks: • to have the electrical connections checked. • to have the safety thermostat L1 checked. • to have the magnet valve cleaned or replaced oil heater IDS 45 / IDS 80...
Page 16
• to have the nozzle replaced. Device switches off; operating display Sealing of the magnet valve faulty Have the magnet valve replaced by the customer permanently illuminated in green service. oil heater IDS 45 / IDS 80...
Page 18
1. Switch the device off as described in the Shutdown chapter. 2. Wait until the device has cooled down completely. 6. Have the combustion chamber cleaned by the customer service. 7. Assemble the components in reverse order. oil heater IDS 45 / IDS 80...
1690 x 620 x (length x width x height) 965 mm 1050 mm Minimum distance to walls or other objects rear sides front Permitted fuel EL fuel oil, diesel EL fuel oil, diesel or kerosene or kerosene oil heater IDS 45 / IDS 80...
Page 22
Overview of spare parts IDS 45 Note! The position numbers of the spare parts differ from those describing the positions of the components mentioned in these instructions. oil heater IDS 45 / IDS 80...
Page 23
Power cord support Switch Stop button protection Fuel tank Thermostat plug Fuse Tank cap Thermostat plug cover Solenoid valve cable Wheel axle Power cord Cable fastener nut Wheels axle support bracket Lamp Cable fastener Wheel oil heater IDS 45 / IDS 80...
Page 24
Overview of spare parts IDS 80 Note! The position numbers of the spare parts differ from those describing the positions of the components mentioned in these instructions. oil heater IDS 45 / IDS 80...
Page 25
25 Suction pipe Flame control box Cable fastener 26 Brass fitting Support plate Cable fastener nut 27 Power cord support Switch Stop button protection 28 Fuel tank Solenoid coil Fuse 29 Tank cap oil heater IDS 45 / IDS 80...
The icon with the crossed-out waste bin on waste electrical or electronic equipment stipulates that this equipment We – Trotec GmbH – declare in sole responsibility that the must not be disposed of with the household waste at the end of product designated below was developed, constructed and its life.