Setting The Parameters; Setting The Date And Time - Baxi POWER HT+ 1.50 User Manual

Hide thumbs Also See for POWER HT+ 1.50:
Table of Contents

Advertisement

6 Settings
Tab.16
Temps / mode CH1 – Temps / mode CH2 – Temps / mode CH3 menu
Parameter number
Heating
Heating
Heating cir­
circuit 1
circuit 2
cuit 3
700
1000
1300
710
1010
1310
712
1012
1310
6.2

Setting the parameters

Fig.7
18. February 2014
Tuesday
1.5 bar
MENU
Fig.8
Set time and date
Hours / minutes
22
POWER HT +
Parameter
Operating
mode
Comfort
setpoint
Reduced
temp setpoint
14:13
MENU
MW-3000052-EN-02
12:00
MENU
MW-3000055-EN-02
Description
The control unit is installed on the boiler:
Off : heating is deactivated.
Timed : the heating is dependent on the timer pro­
gram.
Reduced : heating is in permanent reduced mode.
On : heating is in permanent reduced mode.
The control unit is installed as a room temperature
control system:
Off : the boiler starts up when the room tempera­
ture falls below the frost protection set point.
Timed : the heating is dependent on the timer pro­
gram.
Reduced : the room temperature set point is the
reduced set point (Parameters 712, 1010, 1310)
On : the room temperature set point is the comfort
set point (Parameters 710, 1010, 1310)
6.2.1

Setting the date and time

1. Press the
key to access the parameters.
MENU
2. Select the Set time and date menu by turning the
3. Confirm the menu selection by pressing the
The parameter Hours / minutes appears.
4. Confirm the parameter selection by pressing the
The parameter flashes, it can be modified.
5. Modify the parameter by turning the
6. Confirm the setting by pressing the
7. Set the other parameters if necessary.
Important
Press the
key to return to the main display.
MENU
For more information, see
List of user parameters, page 20
Factory setting
On
20 °C
16 °C
button.
button.
button.
button.
button.
7609475 - v09 - 22072020