6. OPTIONS AND AUXILIARY EQUIPMENT
(1) Selection
Use a combination of servo amplifier, brake unit and resistor unit listed below.
Brake unit
FR-BU2-H15K
FR-BU2-H30K
FR-BU2-H55K
FR-BU2-H75K
(2) Brake unit parameter setting
Normally, when using the FR-BU2-H, changing parameters is not necessary. Whether a parameter
can be changed or not is listed below.
Resistor unit
FR-BR-H15K
FR-BR-H30K
FR-BR-H55K
MT-BR5-H75K
Parameter
No.
Name
0
Brake mode switchover
1
Monitor display data selection
2
Input terminal function selection 1
3
Input terminal function selection 2
77
Parameter write selection
78
Cumulative energization time
carrying-over times
CLr
Parameter clear
ECL
Alarm history clear
C1
For manufacturer setting
Number of
Permissible
connected
continuous
units
power [kW]
1
0.99
1
1.99
1
3.91
1
7.5
Change
possible/
impossible
Impossible
Possible
Impossible
6 - 10
Total
Applicable servo
resistance
[ ]
32
MR-J2S-350A4/B4
16
MR-J2S-500A4/B4
MR-J2S-700A4/B4
MR-J2S-11KA4/B4
8
MR-J2S-11KA4/B4
MR-J2S-15KA4/B4
MR-J2S-22KA4/B4
6.5
MR-J2S-22KA4/B4
Remarks
Do not change the parameter.
Refer to the FR-BU2-(H) Brake Unit
Instruction Manual.
Do not change the parameter.
amplifier