f To cancel, select [CANCEL].
Note
f [LENS CALIBRATION] cannot be executed when the [PROJECTOR SETUP] menu → [LENS] → [LENS TYPE] is set to [NOT SELECTED].
f [PROGRESS] is displayed in the menu during lens calibration. The operation cannot be canceled during calibration.
f [INCOMPLETE] is displayed when the lens calibration is not performed correctly.
f The origin position of the lens mounter and the home position of the projection lens are automatically updated when the lens shift calibration
is performed. The home position is an origin position of the lens shift (vertical position and horizontal position of the lens) based on the
calibration result. It does not match with the optical image center position.
f The home position varies depending on the projection lens type. For details, refer to "Lens shift range" (x page 76).

[OPERATION SETTING]

Set the operation method of the projector.
The settings are reflected when "Initial setting (operation setting)" (x page 63) in the [INITIAL SETTING]
screen is already set.
If you change the settings while using the projector, the duration until the luminance of light source decreases by
half may shorten or the luminance may decrease.
Setting [OPERATING MODE]
1)
Press as to select [OPERATION SETTING].
2)
Press the <ENTER> button.
f The [OPERATION SETTING] screen is displayed.
3)
Press as to select [OPERATING MODE].
4)
Press qw to switch the item.
f The items will switch each time you press the button.
[NORMAL]
*1
[ECO]
*1
[USER1]
[USER2]
[USER3]
*1 The runtime is an estimation when the [PICTURE] menu → [DYNAMIC CONTRAST] is set to [3].
5)
Press as to select [APPLY].
6)
Press the <ENTER> button.
f The confirmation screen is displayed.
7)
Press qw to select [OK], and press the <ENTER> button.
Note
f The [OPERATING MODE] setting does not return to factory default setting even if the [PROJECTOR SETUP] menu → [INITIALIZE] → [ALL
USER DATA] is executed.
f The estimated runtime is a time for the luminance to decrease to half.
f If the consolidated runtime of the projector exceeds 20 000 hours, replacement of the components inside the projector may be required. The
consolidated runtime can be confirmed in the [STATUS] screen. Refer to the [PROJECTOR SETUP] menu → [STATUS] for details.
Setting [MAX LIGHT OUTPUT LEVEL]
Adjust the maximum level to correct screen brightness according to the changes in brightness of the light source.
1)
Press as to select [OPERATION SETTING].
2)
Press the <ENTER> button.
f The [OPERATION SETTING] screen is displayed.
3)
Press as to select [MAX LIGHT OUTPUT LEVEL].
4)
Press qw to adjust.
152 - ENGLISH
Chapter 4 Settings — [PROJECTOR SETUP] menu
Set this item when high luminance is required. The estimated runtime is approximately 20 000 hours.
The luminance will decrease compared to [NORMAL], but set this item to increase the expected life of
the light source. The estimated runtime is approximately 24 000 hours.
Set [MAX LIGHT OUTPUT LEVEL] and [LIGHT OUTPUT] individually.