Chapter 7 Appendix — Precautions for attaching the Ceiling Mount Bracket

Precautions for attaching the Ceiling Mount Bracket

f When installing the projector to a ceiling, use the Ceiling Mount Bracket (Model No.: ET-PKD520H (for High
Ceilings), ET-PKD520S (for Low Ceilings)) together with the Ceiling Mount Bracket (Model No.: ET-PKD520B
(Projector Mount Bracket)).
Model No.: ET-PKD520H (for High Ceilings), ET-PKD520S (for Low Ceilings), ET-PKD520B (Projector
Mount Bracket)
f Attach the drop-prevention set supplied with the Ceiling Mount Bracket to the projector body when installing.
Consult your dealer if the separate drop-prevention set (hexagon head screw with captive washer (M10 x 40),
wire rope: TTRA0143) is required.
f Ask a qualified technician to do the installation work such as mounting the projector on the ceiling.
f Panasonic takes no responsibility for any damage to the projector resulting from use of the Ceiling Mount
Bracket other than the Panasonic product, or an inappropriate choice of location for installing the Ceiling Mount
Bracket, even if the warranty period of the projector has not expired.
f Immediately remove the product that is not in use anymore by asking a qualified technician.
f Refer to the figure of the screw holes to fix the projector as shown below, and use the screws with sufficient
length that can reach the embedded nut.
f Use a torque screwdriver or Allen torque wrench to tighten the screws to their specified tightening torques. Do
not use electric screwdrivers or impact screwdrivers.
f For details, refer to the Installation Instructions of the Ceiling Mount Bracket.
f The model numbers of accessories and optional accessories are subject to change without prior notice.
r Specification for the screw holes to fix the projector (projector bottom view)
Unit: mm
250 - ENGLISH
Screw holes to fix the projector
M6
Embedded nut (thread engagement depth)
Screw tightening torque: (M6) 4 ± 0.5 N·m
Thread engagement depth
27 (1-1/16")
M6
10 (13/32")
27 (1-1/16")
Screw hole maximum
depth
Embedded nut