Fault
Appliance door opens too
wide when activated.

Error code / Fault display / Signal

Fault
E:2060 lights up.
E:2130 lights up.
E:3000 lights up.
E:3100 lights up.
E:3200 or indicator for wa-
ter supply lights up.
1
Depending on the appliance specifications
48
Cause
Door is not correctly adjus-
ted.
Cause
Appliance has detected cal-
cified heating element.
Intake opening of Zeolith
container is covered by
items of tableware.
Water protection system is
activated.
Water protection system is
activated.
Supply hose is kinked.
Water tap is turned off.
Water tap is jammed or
furred up.
The filters in the water con-
nection of the supply or
AquaStop hose are blocked.
Troubleshooting
Adjust the appliance door as de-
scribed in the installation instruc-
tions.
Troubleshooting
Descale the appliance.
1.
Operate the appliance with the wa-
2.
ter softening system.
Re-arrange the tableware in the ap-
pliance so the "Intake opening of
the Zeolith container " → Page 15
is no longer obstructed.
Turn off the water tap.
1.
Call "Customer Service"
2.
→ Page 62.
Turn off the water tap.
1.
Call "Customer Service"
2.
→ Page 62.
Install the supply hose without
kinks.
Turn on the water tap.
Turn on the water tap.
The flow rate must be at least 10 l/
min when the water supply is open.
Switch off the appliance.
1.
Pull out the mains plug.
2.
Turn off the water tap.
3.
Unscrew the water connection.
4.
1