MULTISPAN UTC-111P Operating Manual

MULTISPAN UTC-111P Operating Manual

Pid temperature controller

Advertisement

Quick Links

OPERATING MANUAL
OPERATING MANUAL
PID TEMPERATURE CONTROLLER
PID TEMPERATURE CONTROLLER
UTC-111P, 211P & 411P
UTC-121P,221P & 421P
1 2 3 4
TUNE
SET

Technical Specification

Technical Specification
Model
Display
UPPER:- 4 Digit 7 seg 0.56",red LED Display
Size(HXWXD)
96 X 96 X 50 mm
Panel Cutout
92 X 92 mm
Input
Temperature
Range
Control Action
Output
Power Supply
Protection Level
(As per request)
Operating
Temperature
Note:
1) If Sensor Connection is reversed, Display will show "
2) If Sensor is not connected, Display will show
3) Every time the instrument is turned ON, Following pattern will be displayed
POWER ON
8 8 88
All digit segment will be turned ON for 3 sec
j
Previous or default sensor input will be displayed for 2 sec
1 2 3 4
Process Value
Connection Diagram
Connection Diagram
20
19
18
17
~
100
250V AC
!
50/60 Hz
4VA
N
L
1
2
3
4
UTC-111P,211P,411P
UTC 111P
ºC
PV
ENT
UTC 111P
UTC 211P
72 X 72 X 85 mm
J, K, PT-100 (selectable)
J: 0 to 600°C / K: 0 to 1200°C /
PT-100: -99 to 400ºC /PT.1: -99.0 to 400.0°C
PID /TP/ ON-OFF (selectable)
1 relay, 1 C/O contact, 230V AC, 5A ; 1 SSR,12V DC, 30mA DC
100 to 250V AC, 50 / 60 Hz, Approx 4VA
IP-65(Front side) AS per IS/IEC 60529:2001
0°C To 55°C
16
15
14
13
12
11
-
+
TC
O/P
RTD
S.S.R
RELAY
C
NC
NO
5
6
7
8
9
10
UTC 211P
ºC
0 1 2 3
PV
R
TUNE
SET
ENT
UPPER:- 4 Digit 7 seg 0.39",red LED Display
68 X 68 mm
Relative
Humidity
SRE
" message.
Open
message.
L
1
100
~
250V AC
TC
50/60 Hz
2
N
4VA
!
RTD
3
NO
4
C
RELAY1
NC
5
6
-
O/P
S.S.R
7
Page - 1
UTC 411P
1 2 3 4
°
C
R
TUNE
UTC 411P
48 X 48 X 95 mm
44 X 44 mm
Up to 95% RH Non Condensing
8
9
-
L
1
~
~
100
100
10
250V AC
250V AC
50/60 Hz
50/60 HZ
4VA
4VA
N
2
!
!
11
3
NC
12
C
4
13
R1
NO
14
5
www.multispanindia.com
6
TC
7
-
RTD
8
9
10

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UTC-111P and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MULTISPAN UTC-111P

  • Page 1 OPERATING MANUAL OPERATING MANUAL PID TEMPERATURE CONTROLLER PID TEMPERATURE CONTROLLER UTC-111P, 211P & 411P UTC-121P,221P & 421P UTC 111P ºC 1 2 3 4 UTC 211P ºC 0 1 2 3 UTC 411P 1 2 3 4 ° TUNE TUNE...
  • Page 2 0 6 0 0 C T R L Control Action P I D PID/TP/ON-OFF O N O F Relay Mode R L y Press H E A T C O O L Press key to Save & Exit www.multispanindia.com UTC-111P,211P,411P Page - 2...
  • Page 3 0.1°C to 50.0°C Off-set correction -20°C to +20°C -20.0°C to +20.0°C Delay Time 1 sec To 999 sec -20.0°C to +20.0°C PB 2 2.0 to 20.0 2.0 to 20.0 CT 2 4 to 30 4 to 30 UTC-111P,211P,411P Page - 3 www.multispanindia.com...
  • Page 4 3) Fusible resistor must not be replaced by operator. Product improvement and upgrade is a constant procedure. So for more updated operating information and support, Please contact our helpline : +91-9978991474/76/82 or Email at marketing@multispanindia.com Ver: 05-2017 UTC-111P,211P,411P Page - 4 www.multispanindia.com...

This manual is also suitable for:

Utc-211pUtc-411p

Table of Contents