*Measured from start of VXIbus cycle until relay coil is fully energized.
1260-100X Specifications A-2
Power Consumption
(without plug-ins)
Power Available
(per plug-in)
Cooling (worst-case
plug-in configuration)
Temperature
Relative Humidity
Altitude
Vibration
Shock
Bench Handling
Emissions
Susceptibility, Safety
Mean Time Between
Failures (MTBF)
Mean Time To Repair
(MTTR)
1260-100X User Manual
+5V:
1.0A
+12V: 0A
+24V: 0A
+5V:
2.5A
+12V: 1.0A
+24V: 1.0A
Airflow:
3.0 liters/sec
Backpressure:
0.7 mm H
Operating:
0°C to +55°C
Non-operating:
-40°C to +70°C
95% RH non-condensing
Operating:
10,000 ft.
Non-operating:
15,000 ft.
0.013 in. P-P, 5 Hz to 55 Hz; meets
MIL-T-28800C Type III, Class 5,
Style F
30g, 11 ms, 1/2 sine wave
4 inch drop at 45°
EN61326: 1997+A1:1998, Class A
EN61010-1:1993+A2:1995
646,921hours, MIL-HBK-217,
o
ground-benign, 25
C
Replace plug-in: 5 min.
Replace other:
<30 min.