IMPORTANT: Ensure that the electricity supply is switched off before connecting. Your oven is
intended for permanent installation.
Your appliance must be connected to fi xed wiring via the use of a double pole switched outlet with at least
3mm contact separation. The isolation switch must be accessible after installation (see technical data for
fuse rating). We recommend the use of an RCD device as additional protection.
We strongly recommend the appliance is connected by a quali ed electrican who is a member of the
N.I.C.E.I.C who will comply with the I.E.E and any local regulations.
The terminology DOUBLE POLE -/+ means that both the live and neutral supplies are switched and
disconnected at the same time.
The terminations labelled SUPPLY are connections for the internal house wiring and the terminations
labelled LOAD are for connection to the appliance.
IMPORTANT: The wires in the mains lead are coloured in accordance with the following code:-
Blue........ Neutral
Brown......Live
Green and Yellow.....Earth
As the colours of the wires in the mains lead of this appliance may not correspond with the coloured
markings identifying the terminals in your spur box, proceed as follows;
The wire which is coloured blue must be connected to the terminal which is marked with the letter 'N' or
coloured 'BLACK'. The wire which coloured brown must be connected to the terminal which is marked with
the letter 'L' or coloured RED. The green and yellow earth 'E' should be connected to the terminal marked
with the following symbol '
The appliance may be connected to the mains supply only by a competent person.
The mains lead must not be clamped, bent, trapped, or come into contact with hot parts of the appliance.
If the mains lead is damaged, it must be replaced by a quali ed person (mains cable must not be
longer than 2m for safety reasons). It should be routed away from the appliance and not trapped between
the appliance and the wall.