7. ALARMS

7.1 Overview

There are seven alarm conditions which gen-
erate both aural and visual alarms.
When an alarm setting is violated, the buzzer
sounds and the name of the alarm being vio-
lated appears on the display. The alarm icon
also appears on the Plotter 1, Plotter 2 and
Highway displays. This occurs on both navi-
gators when they are sharing data.
Alarm status is output to external equipment
through the DATA1 port and the DATA4 port
when it outputs data in NMEA format.
34° 23.456´ N 135° 45.678´ E
Alarm message
Arrival alarm
Speed alarm
Alarm
icon
Press CLEAR to silence beep
Press
CLEAR
Press CLEAR to close window
Figure 7-1 Location of alarm
messages and alarm icon
Clearing the aural and visual alarms
Press the [CLEAR] key. When the navigators
are sharing data, the "reset alarm signal" is
transmitted to the other navigator to clear au-
ral and visual alarms there.
Disabling an alarm
Select OFF instead of alarm name on the ap-
propriate menu. This disables the alarm on
both navigators when they are sharing data.
7.2 Arrival Alarm, Anchor
Watch Alarm
Arrival alarm
The arrival alarm informs you that own ship
is approaching a destination waypoint. The
area that defines an arrival zone is that of a
circle which you approach from the outside
of the circle. The alarm will be released if own
ship enters the circle.
Own ship's
position
Figure 7-2 How the arrival alarm works
1) Press the [MENU ESC] key.
DGPS 3D
BRG
2) Press [4] to display the ALARM SET-
234°
TINGS menu.
CSE
345°
Arrival/Anchor
RNG
123
nm
XTE
SPD
12.3
kt
Ship Speed
Ship Speed
Next Page
ENT : Enter
3) Press
4) Press t or s to select Arr.
5) Press
6) Key in alarm range (0.001–9.999 nm).
7) Press the [NU/CU ENT] key.
8) Press the [MENU ESC] key.
When own ship nears a waypoint by the range
set here, the buzzer sounds and the message
"Arrival alarm" appears.
Destination
waypoint
ALARM SETTINGS
Arr.
Alarm Range
0.100nm
On
Alarm Range
0.050nm
In
Speed Rage
000.0 ~ 025.0kt
: Select
MENU : Escape
Figure 7-3 ALARM SETTINGS
menu, page 1/2
or
to select Arrival/Anchor.
to select Alarm Range.
Alarm
setting
: Alarm range
1/2
Anc.
Off
Off
Over
Over
Off