12.6 C70, calibration of Network and NMEA
When calibration code C70 is selected, the LCD arrows for all functions will be
displayed
12.6.1 C70 (RET)
To return to the normal mode, press SET.
12.6.2 C71 (OFF KEY)
(On) = Sound when push buttons are pressed. (OFF) = no sound.
12.6.3 C72 (d0 SEA)
Damping of speed and course over ground (SOG/COG), affecting the complete Nexus
Network and NMEA output.
d0 = no damping. d1 = 2 sec, d2 = 5 sec, d3 = 10 sec, d4 = 20 sec, d5 = 40 sec,
d6 = 1.20 min, d7 = 2.40 min, d8 = 5 min and d9 = 10 min.
12.6.4 C73 (OFF BSP)
(OFF) = FI-30 log transducer. (On) = NMEA log transducer.
If you want to use a NMEA transducer (connected to the NMEA input, you have to set
C73 to On. The Server will then transmit this information on the Nexus Network to all
connected instruments.
After you have changed this setting, you have to restart the system
12.6.5 C74 (OFF DEP)
(OFF) = FI-30 depth transducer. (On) = NMEA depth transducer.
If you want to use a NMEA transducer (connected to the NMEA input, you have to set
C74 to On. The Server will then transmit this information on the Nexus Network to all
connected instruments.
After you have changed this setting, you have to restart the system
12.6.6 C75 (OFF CMP)
(OFF) = FI-30 compass transducer. (On) = NMEA compass transducer.
If you want to use a NMEA transducer (connected to the NMEA input, you have to set
C75 to On. The Server will then transmit this information on the Nexus Network to all
connected instruments.
After you have changed this setting, you have to restart the system
47