Input Parameters - Bosch CL400 Manual

Hide thumbs Also See for CL400:
Table of Contents

Advertisement

5- -2
R5REQ
5.2.1

Input Parameters

P0
P1
P2
Parameter
Attribute
P0
W
This parameter determines the type of a data area. Here, for each job, a data
storage area of 16 words is reserved for the protocol-specific parameters.
Possible data storage areas are:
D Data module 44
H
D Data buffer 64
H
D Data field 43
H
The user must always reserve 16 words per job for job-specific parameters.
Parameter
Attribute
P1
W
If a data module is determined by P0 as a data storage area, P1 indicates the
data module number. In other cases, P1 is meaningless, and should be re-
served with 16#FFFF.
Applicable values are:
D 0 to 511
D 16#FFFF
Parameter
Attribute
P2
W
This is the location where the start address for the job parameters in the se-
lected data storage area is determined.
Description
Data type
Description
Data type attribute
Description
Byte offset