2.8
Technical Data
1070 072 196-101 (00.06) GB
Technical Data
Interfaces
Baudrates V.24/20 mA interface
Current uptake internally
D 5V voltage supply
D +12V ISO voltage supply
Resistance against conducted interfer-
ences
Max. number COM-E per controller
Ambient temperature range
Storage temperature range
Width
Weight
Protection degree
Place and way of installation
Hardware
COM-E
D V.24/20 mA as per guideline "VDI
2880 Blatt 2"
D 20mA interface is electrically iso-
lated
600 to 57600 bd
500 mA typical
70 mA + 20 mA per active current loop
As per EN 61 131-2
5
0 to +55 C
--25 to +70 C
1 slot
300 g
Protection degree IP20 as per DIN
VDE 0470-1, installed in housing
The COM-E can, if inserted in a card
rack, be installed in a control cabinet
horizontally or vertically (if the ambient
temperature is reduced to 40 C).
2- -21