MIDI Implementation

Model:
V-160HD
Date:
July 12, 2021
Version:
1.04
Symbol
Item
Setting Range
n
MIDI Channel
Fixed at 00H

1. MIDI Messages Received at MIDI IN

ÃSystem Exclusive Messages
Status
Data Byte
F0H
iiH,ddH,...,eeH
F0H:
Status of system exclusive message
ii= ID number:
This is the ID to recognize manufacturer of the exclusive
message (manufacturer ID). The manufacturer ID of Roland is
41H. The ID numbers of 7EH and 7FH are expansion of MIDI
standards and used as universal non-realtime message (7EH) of
universal realtime message (7FH).
dd,...,ee= data:
00H–7FH (0–127)
F7H:
EOX (end of exclusive)
ÁData Request 1 (RQ1)
This is the message to request of "send data" to the connected device. Specify data
type and amount using address and size. When this is received, the unit sends the
requested data as "Data Set 1 (DT1)" message in case the unit is in status where the
sending of data is possible and requested address and size are appropriate. If not, the
unit sends nothing.
Status
Data Byte
F0H
41H, 10H, 00H, 00H, 00H, 00H, 02H, 11H, aaH,
bbH, ccH, ssH, ttH, uuH, sum
Byte
Explanation
F0H
Exclusive Status
41H
Manufacturer ID (Roland)
10H
Device ID
00H
1st byte of model ID (V-160HD)
00H
2nd byte of model ID (V-160HD)
00H
3rd byte of model ID (V-160HD)
00H
4th byte of model ID (V-160HD)
02H
5th byte of model ID (V-160HD)
11H
Command ID (RQ1)
aaH
Address upper byte
bbH
Address middle byte
ccH
Address lower byte
ssH
Size upper byte
ttH
Size middle byte
uuH
Size lower byte
sum
Checksum
F7H
EOX (end of exclusive)
* Depending on the data type, the amount of single-time transmission is specified.
It is necessary to execute data request according to the specified first address and
size. Refer to the "2. Parameter Address Map" (p. 3) for address and size.
* See "Example of an Exclusive Message and Calculating a Checksum" (p. 18) for
checksum.
2
Status
F7H
Status
F7H
ÁData Set 1 (DT1)
This is the message of actual data transmission. Use this when you want to set data
to the unit.
Status
Data Byte
F0H
41H, 10H, 00H, 00H, 00H, 00H, 02H, 12H, aaH,
bbH, ccH, ddH, ..., eeH, sum
Byte
Explanation
F0H
Exclusive Status
41H
Manufacturer ID (Roland)
10H
Device ID
00H
1st byte of model ID (V-160HD)
00H
2nd byte of model ID (V-160HD)
00H
3rd byte of model ID (V-160HD)
00H
4th byte of model ID (V-160HD)
02H
5th byte of model ID (V-160HD)
12H
Command ID (DT1)
aaH
Address upper byte
bbH
Address middle byte
ccH
Address lower byte
ddH
Data: actual data to transmit. Multiple byte data is sent in address order.
:
:
eeH
Data
sum
Checksum
F7H
EOX (end of exclusive)
* Depending on the data type, the amount of single-time transmission is specified.
It is necessary to execute data request according to the specified first address and
size. Refer to the "2. Parameter Address Map" (p. 3) for address and size.
* See "Example of an Exclusive Message and Calculating a Checksum" (p. 18) for
checksum.
* Data exceeding 256 bytes should be divided into packets of 256 bytes or smaller. If
you send data set 1 successively, set interval of 20 msec or longer between packets.
Status
F7H