5.3.4

To run in Continuous Sequence Mode

1. Follow steps 1 to 2 above and enter the waiting time "delay time" between
each activation.
2. Touch the "Sequence Mode" icon
3. Touch the "Continuous Mode" icon
4. Touch the Check Mark icon to save
5. Touch the X icon to exit
The screen will look similarly to the screen below:
Note: If the sequence mode is set to activate memory cells 1 – 3, and the
delay time is set at 5000 ms, the controller will activate memory 1 to 3
continuously with 5000 ms delay between each activation. The delay time
must be at least 15 ms.
If there is no delay time entered in the setting, the operator has
to press the foot switch or touch the Run icon after each
memory cell is completed to activate the next memory cell.
If delay time is entered in the setting, the controller will activate
the next memory cell in sequence automatically. Delay time
must be at least 15 ms.