Philio PSP01 Manual page 2

Slim multi-sensor
Table of Contents

Advertisement

1. Have Z-Wave
mode.
2. Pressing tamper key three times within 1.5 seconds
will enter association mode.
Association
Note: The device support 2 groups. The group 1 is for
receiving the report message, like triggered event,
temperature, illumination etc. The group 2 is for light
control, the device will send the "Basic Set" command
to this group.
Including a node ID allocated by Z-Wave
inclusion. Excluding a node ID allocated by Z-Wave
Controller means exclusion.
Failed or success in including/excluding the node ID can be
viewed from Z-Wave
TM
Notice 1: Always RESET a Z-Wave
Z-Wave
TM
network.
Notice 2: When the device into NWI mode, any tamper key and
sensor functionality will useless. The NWI will timeout after 30 seconds.
Z-Wave
TM
Notification
After the device adding to the network, it will wake-up once per day in
default. When it wake-up it will broadcast the "Wake Up Notification"
message to the network, and wake-up 10 seconds for receive the
setting commands.
The wake-up interval minimum setting is 30 minutes, and maximum
setting is 120 hours. And the interval step is 30 minutes.
If the user want to wake-up the device immediately, please remove the
front cover, and press the tamper key once. The device will wake-up 10
seconds.
TM
Controller entered association
TM
Controller means
Controller.
TM
device before trying to add it to a
Z-Wave
TM
* Motion Report:
When the PIR motion detected, the device will unsolicited to send the
"Sensor Binary Report" to the nodes in the group 1.
Sensor Type: Motion (0x0C)
Sensor Value: 0xFF
* Tamper Report:
When the 2 tamper keys in the device are pressed over 5 seconds. The
TM
device will into the alarm state. In that state, if any one of the tamper
keys be released, the device will unsolicited to send the "Sensor Binary
Report" to the nodes in the group 1.
Sensor Type: Tamper (0x08)
Sensor Value: 0xFF
* Temperature Report:
When the PIR motion detected, the device will unsolicited to send the
"Sensor Multilevel Report" to the nodes in the group 1.
Sensor Type: Temperature (0x01)
Note: To disable this functionality by setting the configuration setting
N0.5, the bit5 of the value to 1.
*** Temperature differential report ***
This function default is disabled, to enable by setting the configuration
setting NO.6 bit6 to 1.
When the temperature plus or minus three degree Fahrenheit (1.67
degree Celsius), the device will report temperature information to the
nodes in the group 1.
The device will measure the temperature in every 64 seconds. And if
the temperature is over 140 degree Fahrenheit (60 degree Celsius), the
device also report in each measurement.
* Illumination Report:
When the PIR motion detected, the device will unsolicited to send the
2
Message Report