3
PIR Sensitivity
70
0~99
Light
4
99
0~100
Threshold
5
Operation
0
0~127 Operation mode. Using bit to control.
Mode
1 to 100 means the light strength.
PIR sensitivity settings.
0 means disable the PIR motion.
1 means the lowest sensitivity,
99 means the highest sensitivity.
High sensitivity means can detected long
distance, but if there is more noise signal
in the environment, it will re-trigger too
frequency.
Setting the illumination threshold to turn
on the light. When the event triggered
and the environment illumination lower
then the threshold, the device will turn
on the light.
0 means turn off illumination detected
function. And never turn on the light.
1 means darkest.
99 means brightest.
100 means turn off illumination detected
function. And always turn on the light.
Notice: In none test mode, only the
value in 1 to 99 will enable the
illumination detected function and
update the illumination value.
Bit0: 1 means security mode,
0 means home automation mode.
Bit1: 1 means enable test mode,
0 means disable test mode.
Notice:
Bit0 and bit1 will effect when the DIP
Switch setting to program mode.
If bit1 is enabled, the bit0 is useless.
Multi-Sensor
6
Function
4
Switch
8
PIR Re-Detect
3
Interval Time
8
Bit2: Reserved, always 1.
Bit3: Setting the temperature scale.
0: Fahrenheit , 1: Celsius
Bit4: Disable illumination report after
event triggered.
Bit5: Disable temperature report after
event triggered.
Multi-Sensor function switch. Using bit to
control.
Bit0: Reserved, always 1.
Bit1: Disable PIR integrate Illumination.
Bit2: Reserved, always 1.
Bit3: Reserved.
Bit4: Reserved.
Bit5: Reserved.
0~127
Bit6:Enable temperature monitoring.
When this bit enable, the temperature
changed 3 degree Fahrenheit, it will
report.
And also the temperature over 140
degree Fahrenheit, it will report every 64
seconds.
3~127 In the security mode, after the PIR
motion detected, setting the re-detect
time. 8 seconds per tick, and minimum
time is 24 seconds, default tick is 3 (24
seconds).
Setting the suitable value to prevent
received the trigger signal too frequency.
Also can save the battery energy.
Notice: If this value bigger than the
configuration setting NO. 9. There is a
period after the light turned off and the